Record 1Public property record

Document

  • Electrical
  • Foundation
  • HVAC
  • Home Inspection
  • Plumbing
  • Radon
  • Roof
  • Windows

On July 3, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 12010 Criterion Avenue, St. Louis, MO 63138.

Record date

Available findings

  • RadonWork status not resolved

    Radon test conducted in basement over 71 hours (July 3–6, 2026) using RadStar RS300 monitor; average result 2.8 pCi/L, minimum 0.8 pCi/L, maximum 5.0 pCi/L (Test ID# redacted).

  • Home InspectionWork status not resolved

    Whole-home inspection of single-family residence identified multiple deficiencies including missing sump pump, end-of-life water heater, inoperable smoke detectors, basement floor crack with moisture intrusion, and several electrical and plumbing defects.

  • FoundationWork status not resolved

    Basement floor crack is present allowing moisture to seep in and stain the rug causing musty odor; repair recommended via epoxy injection. Basement stairs require support due to noticeable movement when walking up and down them.

  • PlumbingWork status not resolved

    Sump pump is missing from the sump well and requires replacement; 1998 Richmond gas water heater (50 gal) has excessive rust buildup at inlet valves and has reached end of expected lifespan requiring replacement; 2nd-floor tub faucet has bad diverter and slow drain needing clearing.

  • ElectricalWork status not resolved

    Rear exterior outlet is not working with no tripped breakers or GFCI found; all second-floor smoke detectors are inoperable or missing; GFCI outlet in second-floor bathroom will not reset and needs replacement; no GFCI outlet present in basement laundry area.

  • HVACWork status not resolved

    Bryant 72,000 BTU forced-air gas furnace (manufactured 2023) and Bryant 3.5-ton split-system condenser (manufactured 2023) both located in basement and appear functional and satisfactory.

  • RoofWork status not resolved

    Architectural shingle roof on gable design inspected via drone, estimated 1-3 years old, in satisfactory condition; flashings, soffit, fascia, gutters, and downspouts all satisfactory.

  • WindowsWork status not resolved

    Window in the master bedroom will not lock and the lock needs adjustment.