12010 Criterion Avenue
St. Louis, MO 6313838.7897°N, 90.2065°W
1Event
Contributed by:1 contributor

Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- Electrical · Smoke detectors inoperable or missing on second floor · 2026
- Electrical · Rear outlet not working and GFCI outlets missing or faulty · 2026
- HVAC · Furnace and central air system both from 2023 and working well · 2026
- Foundation · Basement floor crack letting moisture in, stairs need support · 2026
- Plumbing · Sump pump missing and water heater rusted and past its lifespan · 2026
Ask this homePowered by Fresh House property intelligence®
ASK ME ABOUT
RECORD SUMMARY
1 documented event
Contributed by: 1 contributor
First documented event: Jul 2026
Latest documented event: Jul 2026
First added to Fresh House: Jul 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
This page contains 1 documented record for 12010 Criterion Avenue, St. Louis, MO 63138, dated in July 2026.
Home Inspection
Home Inspection Document
Inspected Jul 3, 2026Uploaded Jul 8, 20262 files
Documented from uploaded report
Property Professional Uploaded
By
Greensmith Home Inspection llcdocumented Electrical, Foundation, HVAC, and 5 other topics at 12010 Criterion Avenue, St. Louis, MO 63138.
Scope
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Plumbing,
- Radon,
- Roof,
- Windows
Contributor
worked on or inspected it- Home InspectionWhole-home inspection of single-family residence identified multiple deficiencies including missing sump pump, end-of-life water heater, inoperable smoke detectors, basement floor crack with moisture intrusion, and several electrical and plumbing defects.
- RadonRadon test conducted in basement over 71 hours (July 3. 6, 2026) using RadStar RS300 monitor
- ElectricalRear exterior outlet is not working with no tripped breakers or GFCI found; all second-floor smoke detectors are inoperable or missing; GFCI outlet in second-floor bathroom will not reset and needs replacement; no GFCI outlet present in basement laundry area.
- FoundationBasement floor crack is present allowing moisture to seep in and stain the rug causing musty odor; repair recommended via epoxy injection. Basement stairs require support due to noticeable movement when walking up and down them.
- HVACBryant 72,000 BTU forced-air gas furnace (manufactured 2023) and Bryant 3.5-ton split-system condenser (manufactured 2023) both located in basement and appear functional and satisfactory.
- PlumbingSump pump is missing from the sump well and requires replacement; 1998 Richmond gas water heater (50 gal) has excessive rust buildup at inlet valves and has reached end of expected lifespan requiring replacement; 2nd-floor tub faucet has bad diverter and slow drain needing clearing.
- RoofArchitectural shingle roof on gable design inspected via drone, estimated 1-3 years old, in satisfactory condition; flashings, soffit, fascia, gutters, and downspouts all satisfactory.
- WindowsWindow in the master bedroom will not lock and the lock needs adjustment.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedFoundation
✓ documentedElectrical
✓ documentedHVAC
✓ documentedRadon
✓ documentedWindows
✓ documentedSewer
undocumentedMold
undocumentedPest
undocumentedAppraisals
undocumented