12030 Lavida Avenue
Across 7 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes & estimates, not confirmed as performed
Status not stated
Amount documented; completion not confirmed

Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 7 documented records
Fresh House Property Summary
Highlights selected from 7 documented records for this property.
- Electrical · Recalled Stablok breakers in panel require replacement for safety · 2023
- HVAC · Furnace serviced and multiple components repaired or replaced · 2023
- Foundation · Basement shows signs of past moisture intrusion and musty smell · 2023
- Plumbing · Active plumbing leak under kitchen sink with mildew present · 2023
- Roof · Shingle roof has missing and damaged shingles needing repair · 2023
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 7 documented records for 12030 Lavida Avenue, St. Louis, MO 63138, dated from August 2023 through June 2024. The amount summary includes $2,799 with completion status not stated; appraisal values and permit-declared valuations are excluded.
Home Inspection
On August 24, 2023, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 12030 Lavida Avenue, St. Louis, MO 63138.
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Windows
- Home InspectionHome Inspection information documented.
- Roof3-tab shingle roof estimated 10-15 years old has missing and damaged shingles needing repair; tree limbs are contacting/hanging over the roof; gutters are clogged with leaves and debris; fascia and edge shingles at rear of home are damaged.
- PlumbingSigns of a plumbing leak under the kitchen sink with mildew present; missing showerhead in hallway bathroom; missing toilet seats in master and basement bathrooms; water service was off during inspection preventing full plumbing testing; water heater is a GE 40-gallon natural gas unit manufactured in 2010.
- FoundationPoured concrete basement foundation is satisfactory with no structural deficiency; small exterior cracks noted and should be sealed with urethane caulk; basement has a musty smell with signs of previous moisture intrusion, attributed in part to a leaky kitchen sink draining onto the basement bathroom ceiling.
- WindowsOne broken basement window pane was observed and needs to be replaced.
- PestOlder termite damage is present on the wood fence with no active presence observed on the structure; termite/wood-destroying insect treatment is recommended every 3-5 years.
- Electricalsmoke detectors are missing and need replacement. exterior carport outlet needs a new weatherproof cover. tree limbs are pushing on overhead power lines
- HVACthermostat batteries are dead and need replacement
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — Missing screws on furnace
On December 21, 2023, Arch Air Services documented HVAC at 12030 Lavida Avenue, St. Louis, MO 63138.
- HVACInstalled missing screws on sections 2 and 3 of the furnace/fuel unit and leveled the outdoor AC unit; photos included.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Service Call — Lock and chain installed on AC cage
On December 29, 2023, Arch Air Services documented HVAC at 12030 Lavida Avenue, St. Louis, MO 63138.
- $278HVACPerformed diagnostic and service call, then supplied and installed a lock and chain on the AC cage; keys placed in the lock box located on the AC cage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic and Repair — OEM control board replaced
On November 10, 2023, Arch Air Services documented HVAC at 12030 Lavida Avenue, St. Louis, MO 63138.
- $655HVACDiagnosed furnace control board failure sending incorrect voltage to fan and inducer motors, replaced OEM control board restoring heat cycle; additional recommendations noted for dedicated gas shutoff rework, AC cage lock replacement, filter rack installation, and blower wheel cleaning.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Repair Service — Blower wheel replaced, gas line reworked
On November 29, 2023, Arch Air Services documented HVAC at 12030 Lavida Avenue, St. Louis, MO 63138.
- $1,543HVACPerformed diagnostic and service call, reworked gas line to furnace with dedicated shutoff, replaced air filter rack, replaced blower wheel without motor, and cut and replaced lock on equipment cage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic and Repair — Dual capacitor replaced
On June 7, 2024, Arch Air Services documented HVAC at 12030 Lavida Avenue, St. Louis, MO 63138.
- $323HVACDiagnosed condenser unit where compressor would not run, replaced dual capacitor, and confirmed system working fine at time of service; possible compressor issue noted for future monitoring.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Sewer Document
This record documents Sewer at 12030 Lavida Avenue, St. Louis, MO 63138.
- Sewer
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.