Document
- Electrical
- Foundation
- HVAC
- Home Inspection
- Pest
- Plumbing
- Roof
- Windows
On August 24, 2023, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 12030 Lavida Avenue, St. Louis, MO 63138.
- Record date
Available findings
- Home Inspection
Whole-home inspection of single-family property at redacted identified numerous deficiencies across electrical, HVAC, roofing, plumbing, and other systems, with no structural deficiency observed but a good amount of repairs needed.
- Roof
3-tab shingle roof estimated 10-15 years old has missing and damaged shingles needing repair; tree limbs are contacting/hanging over the roof; gutters are clogged with leaves and debris; fascia and edge shingles at rear of home are damaged.
- Plumbing
Signs of a plumbing leak under the kitchen sink with mildew present; missing showerhead in hallway bathroom; missing toilet seats in master and basement bathrooms; water service was off during inspection preventing full plumbing testing; water heater is a GE 40-gallon natural gas unit manufactured in 2010.
- Foundation
Poured concrete basement foundation is satisfactory with no structural deficiency; small exterior cracks noted and should be sealed with urethane caulk; basement has a musty smell with signs of previous moisture intrusion, attributed in part to a leaky kitchen sink draining onto the basement bathroom ceiling.
- Windows
One broken basement window pane was observed and needs to be replaced.
- Pest
Older termite damage is present on the wood fence with no active presence observed on the structure; termite/wood-destroying insect treatment is recommended every 3-5 years.
- Electrical
redacted electric panel with recalled Stablok breakers requires replacement due to safety risks; smoke detectors are missing and need replacement; exterior carport outlet needs a new weatherproof cover; tree limbs are pushing on overhead power lines.
- HVAC
AC compressor (redacted 2017, 2.5-ton) is severely unlevel and surrounded by vegetation; furnace (redacted 2013, 80,000 BTU) is dirty and needs cleaning and service by an HVAC technician; thermostat batteries are dead and need replacement.