Hi, I'm 1216 River Chase Drive. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
1216 River Chase Drive
Across 1 record on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- HVAC · HVAC service trip performed at the property · Sep 2026
- HVAC · R-410A outdoor condenser unit measured with critically low refrigerant pressures · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 1216 River Chase Drive, Arnold, MO 63010, dated in September 2026. The amount summary includes $89 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Trip — Trip fee service visit
- HVAC
Built from Housecall Pro data
- $89HVACTrip fee charged for HVAC service visit at 1216 River Chase Drive.
- HVACPhotograph shows a fan coil unit with manufacturer data plate: Model No. F2RP024H06G, Serial No
- HVACPhotograph shows an HVAC air handler unit with a data plate reading Model No. F2RP024H06G, Serial No
- HVACPhotograph shows an outdoor HVAC condenser unit with a heavily rusted/corroded fan guard and grille on top, and condenser coil fins on the side panels visibly clogged with debris and fibrous material in multiple sections; the unit shows significant weathering consistent with advanced age.
- HVACPhotograph shows an outdoor air conditioning condenser unit on a concrete pad with heavily soiled and clogged condenser coil screens, significant rust and oxidation on the fan guard and top cap, and a removed access panel in the foreground.
- HVACRefrigerant measurement app shows R-410A system with critically low suction pressure of 3.1 psig and liquid pressure of 3.3 psig (both flagged red); vapor saturation -54.0°F, liquid saturation -53.7°F; actual superheat and subcooling unavailable (link tool not connected); delta P -0.2 psig.
- HVACPhotograph shows an outdoor HVAC condenser unit with coil fins heavily packed with dirt, grass clippings, and organic debris; the fan guard exhibits significant rust, and tools are visible on the concrete pad nearby.
- HVACPhotograph shows an outdoor air conditioning condenser unit on a concrete pad with heavily fouled/debris-clogged condenser coil fins, a visibly rusted fan guard on top, and a yellow Fluke digital multimeter strapped to the unit's side with red test leads connected, indicating active electrical testing of the unit.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,