Complete public upload archive

Property records for 1216 River Chase Drive, Arnold, MO 63010

All 1 public upload record returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 1.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Service Trip — Trip fee service visit

  • HVAC

On September 9, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1216 River Chase Drive, Arnold, MO 63010.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$89

    Trip fee charged for HVAC service visit at 1216 River Chase Drive.

  • HVACWork status not resolved

    Photograph shows a fan coil unit with manufacturer data plate: Model No. F2RP024H06G, Serial No

  • HVACWork status not resolved

    Photograph shows an HVAC air handler unit with a data plate reading Model No. F2RP024H06G, Serial No

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit with a heavily rusted/corroded fan guard and grille on top, and condenser coil fins on the side panels visibly clogged with debris and fibrous material in multiple sections; the unit shows significant weathering consistent with advanced age.

  • HVACWork status not resolved

    Photograph shows an outdoor air conditioning condenser unit on a concrete pad with heavily soiled and clogged condenser coil screens, significant rust and oxidation on the fan guard and top cap, and a removed access panel in the foreground.

  • HVACWork status not resolved

    Refrigerant measurement app shows R-410A system with critically low suction pressure of 3.1 psig and liquid pressure of 3.3 psig (both flagged red); vapor saturation -54.0°F, liquid saturation -53.7°F; actual superheat and subcooling unavailable (link tool not connected); delta P -0.2 psig.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit with coil fins heavily packed with dirt, grass clippings, and organic debris; the fan guard exhibits significant rust, and tools are visible on the concrete pad nearby.

  • HVACWork status not resolved

    Photograph shows an outdoor air conditioning condenser unit on a concrete pad with heavily fouled/debris-clogged condenser coil fins, a visibly rusted fan guard on top, and a yellow Fluke digital multimeter strapped to the unit's side with red test leads connected, indicating active electrical testing of the unit.

View 1216 River Chase Drive, Arnold, MO 63010 on Fresh House