Hi, I'm 1216 SOULARD. I only speak from this property's source-backed records — 15 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
1216 SOULARD
Across 15 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Permitted value
Permitted value: the total declared on public permit filings for this address. It reflects amounts applied for or approved. It is not confirmed spending, and it does not mean the work was completed.
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 15 documented records
Fresh House Property Summary
Highlights selected from 15 documented records for this property.
- HVAC · Carrier control board replaced and coil drain pan cap installed · May 2025
- HVAC · Furnace flue and inducer cleared of water; drain repositioned · Nov 2025
- HVAC · Pressure switch replaced and control board reprogrammed · Dec 2025
- HVAC · Outdoor coil leak found; refrigerant and leak sealant added · Aug 2025
RECORD SUMMARY
1 permit record on this page come from the City of St. Louis permit database. Community records come from 1 contributor.
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 15 documented records for 1216 SOULARD, St. Louis, MO, dated from August 2024 through September 2026. The amount summary includes $3,885.55 in completed work across HVAC, $9,560 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Furnace breaker tripped; reset, system works
- HVAC
Built from Housecall Pro data
- $154HVACNormal hours service call: indoor furnace had no power because its breaker was tripped; wiring and breaker inspected with no cause found, breaker reset and system tested working as intended.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Furnace inducer flooded; drain moved
- HVAC
Built from Housecall Pro data
- $219HVACService call found the furnace flue inducer motor and pipe filled with water because the furnace was pitched the wrong way; the drain was moved to the opposite side, all water was removed, and the system was monitored and is working as intended.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — No power to furnace; electrician needed
- HVAC
Built from Housecall Pro data
- $154HVACNormal hours service call: found no power going to the furnace, checked and reset all breakers, partial power in the apartment, and an electrician is needed.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — No power at AC disconnect; electrician needed
- HVAC
Built from Housecall Pro data
- $219HVACService call: found furnace without power because breaker was off, reset breaker and system worked; on the roof the AC had a call for cool but no high voltage at the disconnect, and an electrician will need to be called.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Service call with ATC-3 fuse supplied
- HVAC
Built from Housecall Pro data
- $154HVACNormal hours residential service call with half an hour of labor; an ATC-3 fuse (purple) was supplied.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Control Board Repair — Carrier control board replaced
- HVAC
Built from Housecall Pro data
- $1,179HVACDiagnosed a system not functioning in cool mode, found the control board bad and replaced the Carrier control board, and replaced a missing cap covering the coil drain pan that had let water run down the furnace; system pressures are good.
- HVACPhotograph shows the rear lower panel of a white appliance covered in water droplets, with a white drain hose fitting connected to a black drain port opening; the surrounding tile floor is visibly wet, indicating a water leak at or near the drain connection.
- HVACR-410A superheat (non-TXV) diagnostic shows current superheat of 27° against a required superheat of 23°; system status confirmed as Correct Charge.
- HVACPhotograph shows the base of an HVAC unit on a concrete floor with a red reset/limit button mounted in a black housing, a white cylindrical fitting adjacent to it, and a brass-colored fitting visible at the left edge.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Breaker trips; AC shares circuit with outlets
- HVAC
Built from Housecall Pro data
- $89HVACNormal hours service call: AC found working fine; outlets share a breaker with the AC and the breaker trips, so an electrician is needed to fix wiring in the breaker box.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Ductwork sweating inspected
- HVAC
Built from Housecall Pro data
- $89HVACInspected the system for ductwork sweating during a normal hours service call.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Unrepairable outdoor coil leak; R410A added
- HVAC
Built from Housecall Pro data
- $736HVACService call found a clogged indoor filter and low refrigerant from a small, unrepairable outdoor coil leak; added 2 lbs of R410A and leak sealant.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Vent Addition Estimate — Add vent to third floor bedroom
- HVAC
Option: Option #1 $1,923 (declined)
Built from Housecall Pro data
- $1,923HVACEstimate for adding a vent to the third floor bedroom with new exposed ductwork routed to floor registers; plaster, drywall and flooring repairs are not included.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Repair Service Call — Failed pressure switch replaced
- HVAC
Built from Housecall Pro data
- $739HVACFound a failed pressure switch that caused multiple codes in the control board; reprogrammed the control board and replaced the pressure switch, and the system worked as intended.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Control Board Reprogramming — Control board reprogrammed via NFC
- HVAC
Built from Housecall Pro data
- HVACUsed NFC on the control board and used a phone to reprogram the control board properly.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Loose wire on blower motor wire harness
- HVAC
Built from Housecall Pro data
- $154HVACNormal hours service call and half an hour of labor for a loose wire on the wire harness for the blower motor.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Mini Split Estimate — LG wall mount heat pump estimate, declined
- HVAC
Option: Option #1 $7,637 (declined)
Built from Housecall Pro data
- $7,637HVACEstimate for furnishing and installing an LG wall mount heat pump (12,000 BTU class indoor unit with outdoor heat pump) for heating and cooling a second floor room in unit A, plus a small boom crane; option declined.
Documented warrantyfive-year / ten-year / twenty-yearFrom estimateView details
What this warranty covers
- parts
· source
“All equipment installed by Contractor comes with a manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an estimate. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
AM Permit AM-2024-254831
On August 21, 2024, City of St. Louis documented HVAC at 1216 SOULARD, St. Louis, MO.
Declared on the permit, not confirmed spending or proof of completed work.
Obtained from a public records source; may contain reporting delays or errors.