Hi, I'm 1808 S 10TH ST. I only speak from this property's source-backed records — 9 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
1808 S 10TH ST
Across 9 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Permitted value
Permitted value: the total declared on public permit filings for this address. It reflects amounts applied for or approved. It is not confirmed spending, and it does not mean the work was completed.
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 9 documented records
Fresh House Property Summary
Highlights selected from 9 documented records for this property.
- HVAC · HVAC system had a gas leak work order logged · 2026
- HVAC · Gas pipe connections at HVAC equipment visible at service visits · 2026
- HVAC · Furnace burners photographed lit and unlit during service visits · 2026
- HVAC · A soap bubble visible at a gas pipe fitting during service visit · 2026
RECORD SUMMARY
4 permit records on this page come from the City of St. Louis permit database. Community records come from 1 contributor.
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 9 documented records for 1808 S 10TH ST, St. Louis, MO, dated from November 2017 through October 2026. The amount summary includes $1,679.50 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Trip fee and 0.5 hr labor
- HVAC
Built from Housecall Pro data
- $154HVACTrip fee and half an hour of labor were provided for a service call.
- HVACPhotograph shows the interior of a gas furnace with multiple burner tubes producing active blue flames; the burner assembly, gas crossover manifold, red zip ties securing wiring, and heavy dust/debris accumulation on the furnace floor are visible.
- HVACPhotograph shows the interior of a gas furnace with multiple burner tubes and heat exchanger panels exhibiting heavy rust, corrosion, and debris accumulation; wiring with a red zip tie is also visible near the burner assembly.
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Service — Residential HVAC diagnostic service
- HVAC
Built from Housecall Pro data
- $157HVACPerformed a residential diagnostic service and journeyman labor (0.5 hours) at the service address.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Overtime Service Call — Overtime labor and after-hours trip fee
- HVAC
Built from Housecall Pro data
- $245HVACOvertime labor (Monday-Friday 4pm-9pm) and after-hours trip fee (Saturday and Monday-Friday after 4pm) were provided for a service call.
- HVACPhotograph shows the manufacturer data plate on an outdoor AC condenser unit: Model 4AC13L30P-10A, Serial 1918E51056, HFC-410A refrigerant, 1-phase 60Hz, nominal 208/230V, assembled in West Columbia, SC.
- HVACPhotograph shows a MagicFilter 16x25x1 MERV 8 air filter that is heavily loaded with dust and debris across the entire filter media surface, indicating it is well past its service life and due for replacement.
- HVACPhotograph shows the exterior louvered grille and condenser coil fins of an outdoor HVAC condensing unit; fins appear darkened with accumulated dirt, dust, and debris visible through the louver slots, indicating the coil is in need of cleaning.
- HVACPhotograph shows a white louvered air vent/register with heavy accumulation of dust, hair, and debris visible on the filter or screen behind the slats, indicating the filter is significantly clogged and overdue for replacement or cleaning.
- HVACPhotograph shows a furnace/air handler unit with large round metal supply ductwork overhead and a flexible connector pipe, located in a narrow utility closet that is heavily cluttered with household items, food, and small appliances; a floor-level return air grille is visible at the base of the unit.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Service — Residential overtime diagnostic
- HVAC
Built from Housecall Pro data
- $360HVACPerformed a residential overtime diagnostic with overtime labor.
- HVACPhotograph shows a Fieldpiece app screen displaying live HVAC air-side measurements: Return dry bulb 75.4°F, wet bulb 66.0°F, RH 60.9%, dew point 60.9°F, enthalpy 30.7 BTU/lbm; Supply dry bulb 57.8°F, wet bulb 54.9°F, RH 83.6%, dew point 52.8°F, enthalpy 23.1 BTU/lbm; Delta T 17.6°F. Refrigerant side suction and liquid readings not yet linked.
- UnclassifiedPhotograph shows a combination key lockbox mounted via shackle through a metal hasp on a wood panel door or gate; the lockbox compartment door is open and the key storage area appears empty, with visible surface rust and weathering on the lockbox body.
HVAC

HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Service — Residential diagnostic service with labor
- HVAC
Built from Housecall Pro data
- $764HVACPerformed residential diagnostic service with technician labor at the normal business hours rate and apprentice labor.
- HVACPhotograph shows heavily corroded black pipe with white mineral/scale buildup at a threaded joint connection, with visible water droplets on surrounding concrete wall surfaces indicating active or recent moisture.
- HVACPhotograph shows a dark metal threaded pipe with a 90-degree elbow fitting mounted against a wet galvanized metal panel; the pipe joints and surrounding surface are visibly wet with water droplets and streaking, indicating an active leak at or near the elbow connection.
- HVACPhotograph shows a brass valve mounted on a concrete/stucco wall connected to a corroded pipe via a rubber boot coupling secured with wire wrap; the joint area appears wet or darkly stained, suggesting a possible leak or improper repair.
- HVACPhotograph shows aged/corroded metal pipe with an elbow fitting exhibiting an active water leak; a visible water bubble is present at the threaded joint, with white mineral streaking on the surrounding concrete wall and metal surface.
- HVACboth reported October 15 with no due date provided
- HVACWork order logged for a gas leak associated with the HVAC system
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
AP Permit AP-2023-226586
On January 17, 2023, City of St. Louis documented Plumbing at 1808 S 10TH ST, St. Louis, MO.
Declared on the permit, not confirmed spending or proof of completed work.
Obtained from a public records source; may contain reporting delays or errors.
AM Permit AM-2023-226525
On January 13, 2023, City of St. Louis documented HVAC at 1808 S 10TH ST, St. Louis, MO.
Declared on the permit, not confirmed spending or proof of completed work.
Obtained from a public records source; may contain reporting delays or errors.
AE Permit AE-2022-223374
On November 9, 2022, City of St. Louis documented Electrical at 1808 S 10TH ST, St. Louis, MO.
Declared on the permit, not confirmed spending or proof of completed work.
Obtained from a public records source; may contain reporting delays or errors.
AE Permit AE-2017-132424
On November 27, 2017, City of St. Louis documented Electrical at 1808 S 10TH ST, St. Louis, MO.
Declared on the permit, not confirmed spending or proof of completed work.
Obtained from a public records source; may contain reporting delays or errors.
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.