Property records for 1808 S 10TH ST, St. Louis, MO
All 9 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 9.
Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.
On January 28, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1808 S 10TH ST, St. Louis, MO.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$154
Trip fee and half an hour of labor were provided for a service call.
HVACWork status not resolved
Photograph shows the interior of a gas furnace with multiple burner tubes producing active blue flames; the burner assembly, gas crossover manifold, red zip ties securing wiring, and heavy dust/debris accumulation on the furnace floor are visible.
HVACWork status not resolved
Photograph shows the interior of a gas furnace with multiple burner tubes and heat exchanger panels exhibiting heavy rust, corrosion, and debris accumulation; wiring with a red zip tie is also visible near the burner assembly.
Record 2·Public property record·4
HVAC Diagnostic Service — Residential HVAC diagnostic service
HVAC
On March 25, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1808 S 10TH ST, St. Louis, MO.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$157
Performed a residential diagnostic service and journeyman labor (0.5 hours) at the service address.
Record 3·Public property record
HVAC Overtime Service Call — Overtime labor and after-hours trip fee
HVAC
On July 28, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1808 S 10TH ST, St. Louis, MO.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$245
Overtime labor (Monday-Friday 4pm-9pm) and after-hours trip fee (Saturday and Monday-Friday after 4pm) were provided for a service call.
HVACWork status not resolved
Photograph shows the manufacturer data plate on an outdoor AC condenser unit: Model 4AC13L30P-10A, Serial 1918E51056, HFC-410A refrigerant, 1-phase 60Hz, nominal 208/230V, assembled in West Columbia, SC.
HVACWork status not resolved
Photograph shows a MagicFilter 16x25x1 MERV 8 air filter that is heavily loaded with dust and debris across the entire filter media surface, indicating it is well past its service life and due for replacement.
HVACWork status not resolved
Photograph shows the exterior louvered grille and condenser coil fins of an outdoor HVAC condensing unit; fins appear darkened with accumulated dirt, dust, and debris visible through the louver slots, indicating the coil is in need of cleaning.
HVACWork status not resolved
Photograph shows a white louvered air vent/register with heavy accumulation of dust, hair, and debris visible on the filter or screen behind the slats, indicating the filter is significantly clogged and overdue for replacement or cleaning.
HVACWork status not resolved
HVACWork status not resolved
Photograph shows a furnace/air handler unit with large round metal supply ductwork overhead and a flexible connector pipe, located in a narrow utility closet that is heavily cluttered with household items, food, and small appliances; a floor-level return air grille is visible at the base of the unit.
Record 4·Public property record
HVAC Diagnostic Service — Residential overtime diagnostic
HVAC
On August 29, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1808 S 10TH ST, St. Louis, MO.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$360
Performed a residential overtime diagnostic with overtime labor.
HVACWork status not resolved
Photograph shows a Fieldpiece app screen displaying live HVAC air-side measurements: Return dry bulb 75.4°F, wet bulb 66.0°F, RH 60.9%, dew point 60.9°F, enthalpy 30.7 BTU/lbm; Supply dry bulb 57.8°F, wet bulb 54.9°F, RH 83.6%, dew point 52.8°F, enthalpy 23.1 BTU/lbm; Delta T 17.6°F. Refrigerant side suction and liquid readings not yet linked.
UnclassifiedWork status not resolved
Photograph shows a combination key lockbox mounted via shackle through a metal hasp on a wood panel door or gate; the lockbox compartment door is open and the key storage area appears empty, with visible surface rust and weathering on the lockbox body.
UnclassifiedWork status not resolved
HVACWork status not resolved
Record 5·Public property record·4
HVAC Diagnostic Service — Residential diagnostic service with labor
HVAC
On October 15, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1808 S 10TH ST, St. Louis, MO.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$764
Performed residential diagnostic service with technician labor at the normal business hours rate and apprentice labor.
HVACWork status not resolved
Photograph shows heavily corroded black pipe with white mineral/scale buildup at a threaded joint connection, with visible water droplets on surrounding concrete wall surfaces indicating active or recent moisture.
HVACWork status not resolved
Photograph shows a dark metal threaded pipe with a 90-degree elbow fitting mounted against a wet galvanized metal panel; the pipe joints and surrounding surface are visibly wet with water droplets and streaking, indicating an active leak at or near the elbow connection.
HVACWork status not resolved
Photograph shows a brass valve mounted on a concrete/stucco wall connected to a corroded pipe via a rubber boot coupling secured with wire wrap; the joint area appears wet or darkly stained, suggesting a possible leak or improper repair.
HVACWork status not resolved
Photograph shows aged/corroded metal pipe with an elbow fitting exhibiting an active water leak — a visible water bubble is present at the threaded joint, with white mineral streaking on the surrounding concrete wall and metal surface.
HVACWork status not resolved
both reported October 15 with no due date provided
HVACWork status not resolved
HVACWork status not resolved
Work order logged for a gas leak associated with the HVAC system
Record 6·Official permit record
AP Permit AP-2023-226586
Plumbing
On January 17, 2023, City of St. Louis documented Plumbing at 1808 S 10TH ST, St. Louis, MO.
Permit number
AP-2023-226586
Source status
Issued
Record date
Declared valuation
$400Declared on the permit, not confirmed spending or proof of completed work.
Official source
City of St. LouisSource data last pulled Sep 30, 2026