- HVAC · Second-floor AC unit shutting off and heat exchanger sweating excessively · 2026
- Electrical · Front porch outlet needs caulking and light fixture needs repair · 2026
- Foundation · Basement floor damaged and site grading missing with exposed plumbing and erosion · 2026
- Roof · Roof and gutters in satisfactory condition; air hose left on roof needs removal · 2026
- Plumbing · Two water heaters and sump pump inspected and found satisfactory · 2026
Ask this homePowered by Fresh House property intelligence®
Reading property memory…
RECORD SUMMARY
1 documented event
1 independent contributor
First recorded: Jul 2026
Most recent update: Jul 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
Home Inspection
Home Inspection Document
Inspected Jul 2, 2026 · uploaded Jul 3, 2026
Documented from uploaded report
Property Professional Uploaded
- Home InspectionWhole-home inspection of new construction at redacted identified several deficiencies including site grading issues, a damaged basement floor, a malfunctioning second-floor HVAC unit, and minor electrical defects, while the overall structure was found to be in excellent condition with no major structural issues.
- ElectricalThe exterior outlet at the front porch needs to be fully caulked to prevent moisture seepage, and the busted light fixture over the front porch requires repair.
- FoundationBasement concrete floor was damaged during expansion crack cutting and requires repair; HVAC condensation line is hanging loose and needs a universal suspension clamp to direct drainage over the floor drain; loose handrail along basement stairs needs to be secured; site grading at front of home is missing with exposed sprinkler plumbing lines and an eroded hole at the front corner.
- HVACThe two Lennox furnaces (manufactured 2025) are causing issues — the second-floor air conditioning unit keeps turning itself off while the thermostat increases temperature, and the heat exchanger on the second-floor unit is sweating excessively, indicating the HVAC condensation line may not be fully operational.
- PlumbingTwo Bradford White 50-gallon natural gas water heaters (both manufactured 2025) with PEX supply piping, PVC waste piping, and a standard crock sump pump were inspected and found satisfactory; main water shutoff is located in the basement.
- RoofDrone inspection of gable roof with architectural shingles found satisfactory condition with metal flashings, aluminum soffit and fascia, and metal gutters all satisfactory; an air hose was left on the roof and needs to be removed.
Fresh House generated structured findings from a documented professional record.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedFoundation
✓ documentedElectrical
✓ documentedHVAC
✓ documentedSewer
undocumentedMold
undocumentedPest
undocumentedRadon
undocumentedAppraisals
undocumentedWindows
undocumented