- HVAC · HVAC diagnostic service performed with two hours of labor · Jan 2026
- HVAC · Second HVAC diagnostic service visit performed at the property · Feb 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 1225 Gregan Place, St. Louis, MO 63133, dated from January 2026 through February 2026. The amount summary includes $438 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Diagnostic Service — Diagnostic visit with 2 hours labor
- HVAC
Built from Housecall Pro data
- $349HVACDiagnostic trip fee and two hours of labor performed for HVAC service.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Service — Residential diagnostic service
- HVAC
Built from Housecall Pro data
- $89HVACResidential diagnostic service performed at the property.
- HVACPhotograph shows the interior of an HVAC air handler or furnace with the access panel open, revealing a green control/circuit board with multiple thermostat wire connections (R, C, Y, Y2, G, W terminals), an illuminated green status LED, and evaporator coil fins visible at the top of the enclosure.
- HVACPhotograph shows the interior of a gas furnace with access panel removed, revealing a Honeywell gas valve (model VR8215S1289) bearing an explosion hazard warning label, visibly aged and rusted heat exchanger burner tubes, multiple wiring harnesses, a green control circuit board, a black gas supply pipe, and significant dust and debris accumulation on the cabinet floor.
- HVACPhotograph shows white PVC drain pipes, including a visible cleanout cap/flange, penetrating a cracked and debris-stained concrete surface in a confined crawl space or basement area; a large metal duct is also visible overhead.
- HVACPhotograph shows the interior of a gas furnace with access panel removed, revealing the inducer/draft blower, control board with two amber LEDs illuminated (indicating a fault or error code), wiring harness, and blower motor assembly; flue pipe and ductwork are visible above the unit.
- HVACPhotograph shows a pipe inspection camera screen displaying the interior of a pipe, with visible orange-brown corrosion or mineral buildup along the right wall and a circular pipe cross-section visible at the top of the frame; camera temperature reads 114°F and timestamp reads 02-22-2026 14:28.
- HVAC · document contexttrade/system and scope are not visible as the Description section is collapsed
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.