Hi, I'm 1229 Sherbrooke Road. I only speak from this property's source-backed records — 6 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
1229 Sherbrooke Road
Across 6 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 6 documented records
Fresh House Property Summary
Highlights selected from 6 documented records for this property.
- HVAC · AC, coil, and furnace replaced using existing ductwork · Mar 2025$14k
- HVAC · New fused disconnect and thermostat added with HVAC install · Mar 2025
- HVAC · Seasonal heating maintenance and gas line service performed · Nov 2025
- HVAC · Heating maintenance performed under a residential maintenance plan · Oct 2026
- Plumbing · Water heater installed by a plumber · Feb 2025
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 6 documented records for 1229 Sherbrooke Road, St. Charles, MO 63303, dated from February 2025 through November 2025. The amount summary includes $16,300 in completed work across HVAC and Plumbing; appraisal values and permit-declared valuations are excluded.
Plumbing Water Heater Installation — Customer supplied water heater
- Plumbing
Built from Housecall Pro data
- $700PlumbingInstalled a customer supplied water heater.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC System Installation — AC, coil and furnace system installed
- HVAC
Built from Housecall Pro data
- $14,200HVACInstalled AC, coil, furnace adapting to existing duct work, added fused disconnect, flushed line set and installed non programmable thermostat.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance Invoice — AC cooling preventative maintenance
- HVAC
Built from Housecall Pro data
- HVACPerformed cooling preventative maintenance and cleaning on the AC.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance and Gas Line — Seasonal heating maintenance and gas
- HVAC
Built from Housecall Pro data
- $1,400HVACPerformed seasonal heating maintenance and a gas line service.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge HVAC service visit
- HVAC
Built from Housecall Pro data
- HVACPhotograph shows a Testo digital manifold gauge displaying refrigerant system readings: low-side 121.7 psi / 70.1°, high-side 214.1 psi / 106.2°, in Refrigeration mode.
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Heating Maintenance — Heating maintenance, maintenance plan
- HVAC
Built from Housecall Pro data
- HVACHeating maintenance performed under the Residential Maintenance Plan.
- HVACPhotograph shows a UEI EM152 digital manometer displaying a reading of -3.35, positioned within an HVAC system enclosure with visible wiring and ductwork in the background.
- HVACPhotograph shows a green PCB control board with two DIP switch arrays (ALCD ADF08S 8-position and ALCD ADF07S 7-position), numerous surface-mount resistors, a screw terminal block labeled 'BUS/SENSOR | AIR SENSOR,' and a push-button switch.
- HVACPhotograph shows a UEi EM152 digital differential pressure manometer displaying a reading of -3.51, positioned near HVAC ductwork and wiring in what appears to be an air handler or furnace compartment.
- HVACPhotograph shows a pleated air filter with a red and white cardboard frame being inserted into the filter slot of a metal air handler unit.
- HVACTechnical manual page showing indoor blower operation DIP switch settings for cooling mode blower speed (Switches 5; 6), blower speed adjustment (Switches 7; 8), and blower speed ramping (Switches 9; 10); a handwritten mark appears at the 'Medium High' speed row in TABLE 10.
- HVACPhotograph shows a Fasco brand draft inducer blower motor (Type 70626175, 120V, 60Hz, 3200/3200 RPM, sealed ball bearings) mounted to a furnace inducer housing assembly; copper windings are visible through the motor end.
- HVACPhotograph shows a close-up view of an HVAC condenser unit's louvered fin coil panel, appearing dark and heavily coated with dust and debris; a circular fan shroud or housing is partially visible at the top of the frame.
- HVACPhotograph shows a Capcom brand single-run capacitor (model 27L571S, 4uF, +6/-6%, 50/60Hz, 370VAC, Protected P921, AT0000AFC) being held in front of an HVAC equipment cabinet.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,