- HVAC · Air conditioner checked; system pressures verified good · Apr 2026
- HVAC · AC coil cleaning skipped due to no outdoor water supply · Apr 2026
- HVAC · Furnace seasonal maintenance done; filter replaced · Dec 2025
- HVAC · Furnace flame sensor not cleaned; closet door blocked access · Dec 2025
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 1238 Maple Avenue, St. Louis, MO 63138, dated in April 2026. The amount summary includes $188 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Seasonal Maintenance — Filter changed; flame sensor not
- HVAC
Built from Housecall Pro data
- $89HVACSeasonal maintenance performed; filter (16x20x1) changed, but flame sensor on the furnace was not cleaned because the tight closet door could not be removed to gain access.
- HVACPhotograph shows a gray metal air handler or furnace unit installed in a mechanical closet, with a white PVC pipe (likely condensate drain or flue) extending upward and a white accessory device (possibly a condensate pump) mounted on top.
- HVACPhotograph shows the interior of a gas furnace with the access panel removed, revealing the draft inducer motor, pressure switch, gas valve (with yellow handle), multi-colored wiring harness, ignition/control components, and flue exhaust elbow; PVC piping is visible to the left and debris is present on the floor beneath the unit.
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Air Conditioner Service — No outside water; AC not cleaned
- HVAC
Built from Housecall Pro data
- $99HVACAir conditioner clean and check visit; no water supply going outside so the unit could not be cleaned properly, but gauges showed the system pressures looked good.
- HVACPhotograph shows an exterior hose bib mounted through white vinyl siding with a corroded blue wheel handle, actively dripping water from the spout and leaving a wet streak down the siding below.
- HVACPhotograph shows an outdoor HVAC condenser unit with heavily fouled/darkened coil fins visible through the wire mesh grille; water is pooling on the ground beneath the unit, and a garden hose is visible nearby, suggesting the unit is being or has been washed.
- HVACPhotograph shows a Fieldpiece SMAN Smart Refrigerant Manifold connected to an outdoor AC condenser unit, displaying R-410A refrigerant pressures of approximately 906 psig (low side) and 2088 psig (high side) with associated temperature readings.
- HVACPhotograph shows an outdoor HVAC condenser unit on a concrete pad with the condenser coil grille heavily packed with leaves, dirt, and organic debris; a technician and hoses are visible nearby, suggesting a service visit in progress.
- HVACPhotograph shows an outdoor air conditioning condenser unit mounted on a concrete pad, enclosed within a metal railing structure; the condenser coil fins visible through the wire guard appear heavily soiled with debris accumulation.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.