Property records for 1238 Maple Avenue, St. Louis, MO 63138

All 2 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 2.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Seasonal Maintenance — Filter changed; flame sensor not

  • HVAC

On December 5, 2025, ASSURED HEATING AND COOLING documented HVAC at 1238 Maple Avenue, St. Louis, MO 63138.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$89

    Seasonal maintenance performed; filter (16x20x1) changed, but flame sensor on the furnace was not cleaned because the tight closet door could not be removed to gain access.

  • HVACWork status not resolved

    Photograph shows a gray metal air handler or furnace unit installed in a mechanical closet, with a white PVC pipe (likely condensate drain or flue) extending upward and a white accessory device (possibly a condensate pump) mounted on top.

  • HVACWork status not resolved

    Photograph shows the interior of a gas furnace with the access panel removed, revealing the draft inducer motor, pressure switch, gas valve (with yellow handle), multi-colored wiring harness, ignition/control components, and flue exhaust elbow; PVC piping is visible to the left and debris is present on the floor beneath the unit.

Record 2Public property record

HVAC Air Conditioner Service — No outside water; AC not cleaned

  • HVAC

On April 24, 2026, ASSURED HEATING AND COOLING documented HVAC at 1238 Maple Avenue, St. Louis, MO 63138.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$99

    Air conditioner clean and check visit; no water supply going outside so the unit could not be cleaned properly, but gauges showed the system pressures looked good.

  • HVACWork status not resolved

    Photograph shows an exterior hose bib mounted through white vinyl siding with a corroded blue wheel handle, actively dripping water from the spout and leaving a wet streak down the siding below.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit with heavily fouled/darkened coil fins visible through the wire mesh grille; water is pooling on the ground beneath the unit, and a garden hose is visible nearby, suggesting the unit is being or has been washed.

  • HVACWork status not resolved

    Photograph shows a Fieldpiece SMAN Smart Refrigerant Manifold connected to an outdoor AC condenser unit, displaying R-410A refrigerant pressures of approximately 906 psig (low side) and 2088 psig (high side) with associated temperature readings.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit on a concrete pad with the condenser coil grille heavily packed with leaves, dirt, and organic debris; a technician and hoses are visible nearby, suggesting a service visit in progress.

  • HVACWork status not resolved

    Photograph shows an outdoor air conditioning condenser unit mounted on a concrete pad, enclosed within a metal railing structure; the condenser coil fins visible through the wire guard appear heavily soiled with debris accumulation.