- HVAC · Condenser fan motor and capacitor replaced on commercial unit · Sep 2026
- HVAC · Commercial HVAC unit diagnosed after-hours for a maintenance customer · Jul 2026
- HVAC · Commercial HVAC system diagnosed during normal business hours · Jul 2026
- HVAC · Compressor ran with freezing suction line; dispatched to inspect for refrigerant and airflow issues · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 4 documented records for 12545 Bennington Place, St. Louis, MO 63146. The amount summary includes $1,850 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Diagnostic Service — Commercial HVAC diagnostic service
- HVAC
Built from Housecall Pro data
- $285HVACPerformed a commercial diagnostic service with commercial labor during normal business hours.
- HVACPhotograph shows a rooftop packaged HVAC unit with its side-mounted electrical disconnect box open and exposed, revealing internal disconnect components
- HVACFieldpiece app refrigerant diagnostic shows R-410A system with suction pressure 125.3 psig, liquid pressure 356.6 psig, actual superheat 11.3°F, actual subcooling 6.9°F, and Delta T 18.4°F.
- HVACPhotograph shows a pleated air filter installed in a ceiling/wall return grille with the center pleats visibly collapsed or deformed inward; a handwritten marking is present on the filter media, and a second blue filter layer is partially visible at the bottom edge.
- HVACa partial permit or inspection sticker is affixed to the panel door
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Service — Commercial after-hours diagnostic and labor
- HVAC
Built from Housecall Pro data
- $500HVACCommercial after-hours diagnostic and labor performed for a maintenance customer.
- HVACrefrigerant manifold gauges are visible nearby suggesting an HVAC condenser context
- HVAChandwritten circuit numbers (39; 42) visible on panel door blue marker writing also present on cover
- HVACPhotograph shows a Yellow Jacket dual-gauge Test and Charging Manifold with blue low-side and red high-side pressure gauges scaled for R-410A and R-22 refrigerants, with brass manifold body and hose fittings, date code 2025.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Service — Commercial diagnostic and 1.5 hrs labor
- HVAC
Built from Housecall Pro data
- $335HVACPerformed commercial diagnostic service and 1.5 hours of commercial labor.
- HVACSS2 compressor running with low pressure and freezing suction line temperature at -0.2F since 9/7; technician dispatched to inspect for refrigerant leaks, air restriction issues, and electrical or mechanical deficiencies.
- HVACPhotograph shows plastic-wrapped rectangular object with pink border (consistent with an air filter or insulation panel) stored alongside other plastic bags in a dark utility or storage area.
- HVACPhotograph shows an A-frame evaporator coil with heavy corrosion, rust on fins and copper tubing, significant debris and sediment accumulation in the drain pan area, and visible refrigerant lines and wiring inside an open air handler cabinet.
- HVACPhotograph shows a louvered HVAC vent register with heavy accumulation of dust, lint, and debris coating all visible louver blades and the surrounding metal housing, indicating a significantly restricted airflow condition.
- HVACPhotograph shows a weathered HVAC air handler/RTU cabinet with a handwritten note reading 'DO NOT BLOCK THIS PIPE' and an insulated drain/condensate pipe at the base; surrounding text messages indicate the compressor is off, the unit is frozen and needs 24 hours to thaw before inspection, and that filters are not being used.
- Unclassifiedambient probe temperature reads 98°F and device timestamp shows 14/08/2024 at 08:09:15
- UnclassifiedPhotograph shows a tile floor covered with soiled debris including dirty plastic bags, a burlap sack, a plastic food container lid, a cardboard box with pink foam insulation wrapped in plastic sheeting, a rope mop head in a blue mesh bag, and miscellaneous packaging materials.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance — HeatCraft condenser motor and capacitor
- HVAC
Built from Housecall Pro data
- $730HVACPerformed commercial diagnostic service and 3 hours of commercial labor, and supplied a HeatCraft condenser motor and capacitor.
- HVACPhotograph shows the interior of an HVAC air handler cabinet with a blower motor assembly, fan blade, run capacitor (small silver cylindrical component with blue label), and associated electrical wiring (black, yellow, and pink/tan leads) alongside copper piping and sheet metal cabinet walls.
- HVACPhotograph shows the interior of an HVAC condenser unit with a heavily soiled and worn fan motor, a run capacitor (C65V, 4 μF ±5%, 370VAC, manufactured June 2017), condenser fan blade, copper refrigerant lines, and associated wiring.
- HVACPhotograph shows an outdoor HVAC condenser unit with heavily fouled, debris-clogged condenser coil fins; the surrounding area is littered with dead leaves, pine cones, trash, a coiled garden hose, and a displaced white fan grille leaning against the unit.
- HVACpartial panel text reads 'SOR LOCAT[ED] HIND PANEL' (sensor located behind panel) NSF certification mark B2002 is visible on the gauge face
- HVACPhotograph shows a Zero Zone dual-scale (°C/°F) dial thermometer mounted on a commercial refrigeration unit, with the needle reading approximately -15°C / 5°F; unit bears NSF B2002 certification mark.
- HVACPhotograph shows HVAC mechanical equipment; including what appears to be a blower/fan assembly and copper refrigerant or supply lines; viewed through a metal wire cage guard.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this property.