Record 1Public property record

HVAC Diagnostic Service — Commercial HVAC diagnostic service

  • HVAC

On July 2, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 12545 Bennington Place, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$285

    Performed a commercial diagnostic service with commercial labor during normal business hours.

  • HVACWork status not resolved

    Photograph shows a rooftop packaged HVAC unit with its side-mounted electrical disconnect box open and exposed, revealing internal disconnect components

  • HVACWork status not resolved

    Fieldpiece app refrigerant diagnostic shows R-410A system with suction pressure 125.3 psig, liquid pressure 356.6 psig, actual superheat 11.3°F, actual subcooling 6.9°F, and Delta T 18.4°F.

  • HVACWork status not resolved

    Photograph shows a pleated air filter installed in a ceiling/wall return grille with the center pleats visibly collapsed or deformed inward; a handwritten marking is present on the filter media, and a second blue filter layer is partially visible at the bottom edge.

  • HVACWork status not resolved

    a partial permit or inspection sticker is affixed to the panel door

  • HVACWork status not resolved
Record 2Public property record

HVAC Diagnostic Service — Commercial after-hours diagnostic and labor

  • HVAC

On July 3, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 12545 Bennington Place, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$500

    Commercial after-hours diagnostic and labor performed for a maintenance customer.

  • HVACWork status not resolved

    refrigerant manifold gauges are visible nearby suggesting an HVAC condenser context

  • HVACWork status not resolved

    handwritten circuit numbers (39–42) visible on panel door blue marker writing also present on cover

  • HVACWork status not resolved

    Photograph shows a Yellow Jacket dual-gauge Test and Charging Manifold with blue low-side and red high-side pressure gauges scaled for R-410A and R-22 refrigerants, with brass manifold body and hose fittings, date code 2025.

  • HVACWork status not resolved
Record 3Public property record

HVAC Diagnostic Service — Commercial diagnostic and 1.5 hrs labor

  • HVAC

On September 24, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 12545 Bennington Place, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$335

    Performed commercial diagnostic service and 1.5 hours of commercial labor.

  • HVACWork status not resolved

    SS2 compressor running with low pressure and freezing suction line temperature at -0.2F since 9/7; technician dispatched to inspect for refrigerant leaks, air restriction issues, and electrical or mechanical deficiencies.

  • HVACWork status not resolved

    Photograph shows plastic-wrapped rectangular object with pink border (consistent with an air filter or insulation panel) stored alongside other plastic bags in a dark utility or storage area.

  • HVACWork status not resolved

    Photograph shows an A-frame evaporator coil with heavy corrosion, rust on fins and copper tubing, significant debris and sediment accumulation in the drain pan area, and visible refrigerant lines and wiring inside an open air handler cabinet.

  • HVACWork status not resolved

    Photograph shows a louvered HVAC vent register with heavy accumulation of dust, lint, and debris coating all visible louver blades and the surrounding metal housing, indicating a significantly restricted airflow condition.

  • HVACWork status not resolved

    Photograph shows a weathered HVAC air handler/RTU cabinet with a handwritten note reading 'DO NOT BLOCK THIS PIPE' and an insulated drain/condensate pipe at the base; surrounding text messages indicate the compressor is off, the unit is frozen and needs 24 hours to thaw before inspection, and that filters are not being used.

  • UnclassifiedWork status not resolved

    ambient probe temperature reads 98°F and device timestamp shows 14/08/2024 at 08:09:15

  • UnclassifiedWork status not resolved

    Photograph shows a tile floor covered with soiled debris including dirty plastic bags, a burlap sack, a plastic food container lid, a cardboard box with pink foam insulation wrapped in plastic sheeting, a rope mop head in a blue mesh bag, and miscellaneous packaging materials.

Record 4Public property record

HVAC Maintenance — HeatCraft condenser motor and capacitor

  • HVAC

On September 25, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 12545 Bennington Place, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$730

    Performed commercial diagnostic service and 3 hours of commercial labor, and supplied a HeatCraft condenser motor and capacitor.

  • HVACWork status not resolved

    Photograph shows the interior of an HVAC air handler cabinet with a blower motor assembly, fan blade, run capacitor (small silver cylindrical component with blue label), and associated electrical wiring (black, yellow, and pink/tan leads) alongside copper piping and sheet metal cabinet walls.

  • HVACWork status not resolved

    Photograph shows the interior of an HVAC condenser unit with a heavily soiled and worn fan motor, a run capacitor (C65V, 4 μF ±5%, 370VAC, manufactured June 2017), condenser fan blade, copper refrigerant lines, and associated wiring.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit with heavily fouled, debris-clogged condenser coil fins; the surrounding area is littered with dead leaves, pine cones, trash, a coiled garden hose, and a displaced white fan grille leaning against the unit.

  • HVACWork status not resolved

    partial panel text reads 'SOR LOCAT[ED] HIND PANEL' (sensor located behind panel) NSF certification mark B2002 is visible on the gauge face

  • HVACWork status not resolved

    Photograph shows a Zero Zone dual-scale (°C/°F) dial thermometer mounted on a commercial refrigeration unit, with the needle reading approximately -15°C / 5°F; unit bears NSF B2002 certification mark.

  • HVACWork status not resolved

    Photograph shows HVAC mechanical equipment — including what appears to be a blower/fan assembly and copper refrigerant or supply lines — viewed through a metal wire cage guard.

  • HVACWork status not resolved

View 12545 Bennington Place, St. Louis, MO 63146 on Fresh House