Record 1Public property record

Document (06/26/2026)

  • Electrical
  • Foundation
  • HVAC
  • Home Inspection
  • Pest
  • Plumbing
  • Roof
  • Windows

On June 25, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 127 East Marseille Drive, St. Louis, MO 63129.

Record date

Available findings

  • PestWork status not resolved

    Wood Destroying Insect inspection of SFR/Attached Garage at 127 East Marseille Drive found no visible evidence of wood destroying insects; no action or treatment recommended.

  • Home InspectionWork status not resolved

    Whole-home inspection of a single-family property identified deficiencies including driveway concrete damage, rear exterior door trim damage, a chewed-down roof vent stack, tree limbs pushing on power lines, and five windows with broken seals; no structural issues found.

  • RoofWork status not resolved

    Architectural shingle roof estimated 1 year old or newer is installed correctly; one metal vent stack has been chewed down flush and needs to be extended to 6" minimum above the roof line.

  • ElectricalWork status not resolved

    Overhead electrical service with Square D panel (100 amps) in basement is satisfactory; tree limbs are pushing on power lines and Ameren should be contacted to cut them back.

  • HVACWork status not resolved

    Rheem gas furnace manufactured 2001 with new A-coil installed 2020 is functioning correctly; Rheem 2-ton AC condenser manufactured 2020 is functioning correctly; central split system with smart thermostat.

  • PlumbingWork status not resolved

    General Electric 50-gallon natural gas water heater manufactured in 2000 is functioning properly but approaching the end of expected life; copper supply pipes and cast iron waste pipes are satisfactory.

  • FoundationWork status not resolved

    Poured concrete basement foundation is in satisfactory condition with no moisture detected; hairline cracks in the exterior foundation are noted as too small for repairs.

  • WindowsWork status not resolved

    Five windows appear to have broken seals and require repair or replacement, located in the front-facing bedroom, the master bedroom, the living room, and the dining room.

  • PestWork status not resolved

    No termite or pest presence or damage observed at the property.

View 127 East Marseille Drive, St. Louis, MO 63129 on Fresh House