127 East Marseille Drive

Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- Electrical · Tree limbs pushing on power lines need to be cut back · 2026
- Foundation · Basement foundation is satisfactory with no moisture detected · 2026
- Plumbing · Water heater from 2000 is nearing end of expected life · 2026
- Roof · Chewed roof vent stack needs to be extended to proper height · 2026
- Windows · Five windows have broken seals and need repair or replacement · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 127 East Marseille Drive, St. Louis, MO 63129, dated in June 2026.
Home Inspection Document
On June 25, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 127 East Marseille Drive, St. Louis, MO 63129.
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Windows
- Home InspectionWhole-home inspection of a single-family property identified deficiencies including driveway concrete damage, rear exterior door trim damage, a chewed-down roof vent stack, tree limbs pushing on power lines, and five windows with broken seals; no structural issues found.
- PestWood Destroying Insect inspection of SFR/Attached Garage at 127 East Marseille Drive found no visible evidence of wood destroying insects; no action or treatment recommended.
- RoofArchitectural shingle roof estimated 1 year old or newer is installed correctly; one metal vent stack has been chewed down flush and needs to be extended to 6" minimum above the roof line.
- ElectricalOverhead electrical service with Square D panel (100 amps) in basement is satisfactory; tree limbs are pushing on power lines and Ameren should be contacted to cut them back.
- HVACRheem gas furnace manufactured 2001 with new A-coil installed 2020 is functioning correctly; Rheem 2-ton AC condenser manufactured 2020 is functioning correctly; central split system with smart thermostat.
- PlumbingGeneral Electric 50-gallon natural gas water heater manufactured in 2000 is functioning properly but approaching the end of expected life; copper supply pipes and cast iron waste pipes are satisfactory.
- FoundationPoured concrete basement foundation is in satisfactory condition with no moisture detected; hairline cracks in the exterior foundation are noted as too small for repairs.
- WindowsFive windows appear to have broken seals and require repair or replacement, located in the front-facing bedroom, the master bedroom, the living room, and the dining room.
- PestNo termite or pest presence or damage observed at the property.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,