Hi, I'm 1281 Green Falls Drive. I only speak from this property's source-backed records — 2 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
1281 Green Falls Drive
Across 2 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 2 documented records
Fresh House Property Summary
Highlights selected from 2 documented records for this property.
- HVAC · AC condenser fan motor and capacitor replaced · Aug 2026
- HVAC · HVAC service call with trip fee also billed · Aug 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 1281 Green Falls Drive, Fenton, MO 63026, dated in August 2026. The amount summary includes $799 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Maintenance — Condenser fan motor and capacitor
- HVAC
Built from Housecall Pro data
- $799HVACService call with trip fee and condenser fan motor and capacitor work performed.
- HVACPhotograph shows a cylindrical run capacitor with multiple wire terminals (purple, red, yellow, and black wires) connected inside an HVAC unit, with a contactor or relay component visible in the upper left.
- HVACPhotograph shows the internal wiring compartment of an HVAC unit with multiple wire connections (red, black, yellow, green) at a terminal block, with heavy dust and debris accumulation visible on components and connectors.
- HVACthe meter display reads approximately 0.21, with a capacitor, multi-colored wiring, and copper refrigerant lines visible inside the unit
- HVACL9721 1980[...], rated at 100,000 BTU/HR input, 115V/60Hz, equipped for natural gas with LP conversion kit
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge HVAC service visit
- HVAC
Built from Housecall Pro data
- HVACno service line items are listed
- HVACPhotograph shows an open outdoor AC condenser unit with heavily soiled condenser coil fins, significant debris (leaves and dirt) accumulated at the base of the cabinet, a visible run capacitor, aged copper refrigerant lines, and electrical wiring.
- HVACPhotograph shows an outdoor HVAC condenser unit with heavily fouled coil fins; thick accumulation of dirt, dust, and debris covers the entire exterior coil surface, with especially dense buildup along the top edge.
- HVACPhotograph shows a black condenser fan motor with shaft, mounted on the wire grille inside an outdoor AC condenser unit, with multiple colored wires (green, black, red, yellow, orange) connected at its base and a label sticker on the motor body.
- HVACPhotograph shows an outdoor condenser unit with the side panel removed, revealing heavily soiled condenser coil fins clogged with dirt and debris, accumulated leaf and organic debris in the base pan, and a visible run capacitor and copper refrigerant lines.
- HVACPhotograph shows a product hang tag for an HVAC motor (Catalog 5431), rated 1/4; 1/8 HP, 825 RPM, 208; 230 volts, 2.1 amps, extreme 80°C ambient rated, with capacitor included.
- HVACPhotograph shows the exterior condenser coil fins of a residential HVAC unit with visible dirt accumulation, debris streaking, and surface fouling across the fin array.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an outdoor HVAC condenser unit, displaying R410A refrigerant readings: suction-side 151.1 psi with 13.7°F superheat (SH) and liquid-side 326.3 psi with 7.0°F subcooling (SC).
- HVACPhotograph shows an outdoor HVAC condenser unit installed in a narrow side yard between two structures, with visible mesh coil fins and a black refrigerant line set routed along the exterior wall.
- HVACPhotograph shows an outdoor air conditioning condenser unit mounted on a concrete pad with a metal stand, with visible dirt/debris accumulation on the top cap, a white patch on the lower cabinet panel, refrigerant lines running up the house siding, and an electrical disconnect box mounted on the exterior wall nearby.
- HVACPhotograph shows the exterior condenser coil fins of an outdoor HVAC unit heavily packed with compacted dirt, dust, and debris across the entire visible surface, indicating significant restriction to airflow and heat transfer.
- HVACPhotograph shows a disassembled air conditioning condenser top panel lying on grass, with the fan motor mounted to the wire grille and multiple electrical leads disconnected and loose.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,