HVACCompleted work
no service line items are listed
HVACWork status not resolved
Photograph shows an open outdoor AC condenser unit with heavily soiled condenser coil fins, significant debris (leaves and dirt) accumulated at the base of the cabinet, a visible run capacitor, aged copper refrigerant lines, and electrical wiring.
HVACWork status not resolved
Photograph shows an outdoor HVAC condenser unit with heavily fouled coil fins — thick accumulation of dirt, dust, and debris covers the entire exterior coil surface, with especially dense buildup along the top edge.
HVACWork status not resolved
Photograph shows a black condenser fan motor with shaft, mounted on the wire grille inside an outdoor AC condenser unit, with multiple colored wires (green, black, red, yellow, orange) connected at its base and a label sticker on the motor body.
HVACWork status not resolved
Photograph shows an outdoor condenser unit with the side panel removed, revealing heavily soiled condenser coil fins clogged with dirt and debris, accumulated leaf and organic debris in the base pan, and a visible run capacitor and copper refrigerant lines.
HVACWork status not resolved
Photograph shows a product hang tag for an HVAC motor (Catalog 5431), rated 1/4–1/8 HP, 825 RPM, 208–230 volts, 2.1 amps, extreme 80°C ambient rated, with capacitor included.
HVACWork status not resolved
Photograph shows the exterior condenser coil fins of a residential HVAC unit with visible dirt accumulation, debris streaking, and surface fouling across the fin array.
HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge connected to an outdoor HVAC condenser unit, displaying R410A refrigerant readings: suction-side 151.1 psi with 13.7°F superheat (SH) and liquid-side 326.3 psi with 7.0°F subcooling (SC).
HVACWork status not resolved
Photograph shows an outdoor HVAC condenser unit installed in a narrow side yard between two structures, with visible mesh coil fins and a black refrigerant line set routed along the exterior wall.
HVACWork status not resolved
Photograph shows an outdoor air conditioning condenser unit mounted on a concrete pad with a metal stand, with visible dirt/debris accumulation on the top cap, a white patch on the lower cabinet panel, refrigerant lines running up the house siding, and an electrical disconnect box mounted on the exterior wall nearby.
HVACWork status not resolved
Photograph shows the exterior condenser coil fins of an outdoor HVAC unit heavily packed with compacted dirt, dust, and debris across the entire visible surface, indicating significant restriction to airflow and heat transfer.
HVACWork status not resolved
HVACWork status not resolved
Photograph shows a disassembled air conditioning condenser top panel lying on grass, with the fan motor mounted to the wire grille and multiple electrical leads disconnected and loose.