← MAPSOURCE-BACKED RECORDS
131 Countryshire Drive
Lake St. Louis, Missouri, 6336738.7533°N, 90.7880°W
1Event
1Contributor
Fresh House Property Summary
Generated from 1 documented record on this property page.
- Electrical · Missing smoke detector and unprotected outlets need attention · 2026
- HVAC · Original 2013 system working but over 10 years old; service recommended · 2026
- Foundation · Basement wall cracks need epoxy repairs; past moisture near window · 2026
- Roof · Roof in good shape but sloppy tar patch repairs need professional cleanup · 2026
- Plumbing · 2014 water heater and all pipes appear functional and satisfactory · 2026
Ask this homePowered by Fresh House property intelligence®
Reading property memory…
RECORD SUMMARY
1 documented event
1 independent contributor
First recorded: Jun 2026
Most recent update: Jun 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
Home Inspection
Home Inspection Document
Inspected Jun 24, 2026 · uploaded Jun 29, 2026
Documented from uploaded report
Property Professional Uploaded
- Home InspectionWhole-home inspection of single-family residence at 131 Countryshire Dr, Lake Saint Louis, MO 63367; home appears to be in great condition with no structural issues; deficiencies noted in roofing, basement walls, electrical, and laundry.
- PestWood Destroying Insect inspection of SFR/Attached Garage at 131 Countryshire Drive, O'Fallon, MO 63367 found no visible evidence of wood destroying insects; no action or treatment recommended.
- SewerSewer camera inspection of main line from 4-inch PVC to 6-inch green pipe to the MSD tie-in; line is open and flowing and looks good.
- RoofOriginal shingled roof (architectural shingles) is in great shape overall, but small repairs have been made in a sloppy fashion with tar and need to be cleaned up by a professional.
- FoundationBasement walls have common cracks requiring epoxy injection repairs; one crack near the basement window shows signs of previous moisture intrusion, though previous crack repairs appear to be performing properly.
- ElectricalMissing smoke detector in the basement needs replacement; interior electric outlets noted as needing replacement; washing machine outlet in laundry room is not GFCI protected and a GFCI outlet should be installed.
- HVACOriginal Lennox central split system (manufactured 2013) with forced air gas heating and electric split-system cooling is functioning correctly; condenser data plate is faded and unit cannot be sized; annual servicing by a licensed HVAC contractor is recommended for systems over 10 years old.
- PlumbingRheem electric water heater (50 gal, manufactured 2014) appears functional; PEX supply pipes and PVC waste pipes are satisfactory; sump pump present and satisfactory; public sewer system.
Fresh House generated structured findings from a documented professional record.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedSewer
✓ documentedFoundation
✓ documentedElectrical
✓ documentedHVAC
✓ documentedPest
✓ documentedMold
undocumentedRadon
undocumentedAppraisals
undocumentedWindows
undocumented