Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- Electrical · Open neutral outlet and most smoke detectors missing or inoperable · 2026
- HVAC · AC capacitor rusted, ductwork dirty and poorly sealed, uneven airflow · 2026
- Foundation · Front walkway slab has sunk and is a trip hazard · 2026
- Plumbing · Water heater end-of-life, expansion tank leaking, gas shutoffs seized · 2026
- Roof · Roof is about one to two years old and in good condition · 2026
Ask this homePowered by Fresh House property intelligence®
ASK ME ABOUT
RECORD SUMMARY
1 documented event
Contributed by: 1 contributor
First documented event: Jul 2026
Latest documented event: Jul 2026
First added to Fresh House: Jul 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
This page contains 1 documented record for 1316 Westbrooke Terrace Drive, Ballwin, MO 63021, dated in July 2026.
Home Inspection
Home Inspection Document
Inspected Jul 22, 2026Uploaded Jul 28, 20265 files
Documented from uploaded report
Property Professional Uploaded
By
Greensmith Home Inspection llcdocumented Electrical, Foundation, HVAC, and 6 other topics at 1316 Westbrooke Terrace Drive, Ballwin, MO 63021.
Scope
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Sewer,
- Windows
Contributor
worked on or inspected it- Home InspectionWhole-home inspection of single-family property identified multiple deficiencies including seized gas shutoff valves, an end-of-life water heater with leaking expansion tank, a rusted AC capacitor, an open neutral outlet, missing/inoperable smoke detectors, a broken kitchen window pane, and a sunken front walkway trip hazard.
- SewerSewer lateral lines are open and flowing; no damages and no blockages observed from the city main tap-in to the main sewer stack in the basement; entire line appears to be ABS.
- PestWood Destroying Insect inspection of SFR/Attached Garage at 1316 Westbrooke Terrace Drive, Ballwin, MO found no visible evidence of wood destroying insects; no action or treatment recommended.
- ElectricalOne living room outlet has an open neutral wire that needs corrected; most smoke detectors are inoperable or missing and functioning smoke detectors need to be installed throughout the home; service panel is Square D 100-amp with breakers, appears functional.
- FoundationA section of the front concrete walkway has sunk, creating a trip hazard; recommendation is to jack up the sunken slab back to level; poured concrete foundation is satisfactory with no structural issues observed.
- HVACGoodman 3.5-ton AC condenser (manufactured 2018) is operating properly but the capacitor has rusted and needs replacement; International Comfort gas furnace (97,000 BTU, manufactured 2020) is performing properly; airflow is uneven in certain rooms suggesting ductwork may need cleaning.
- PlumbingGas water heater (AO Smith, manufactured 2000) has reached end of expected lifespan and the expansion tank exhibits multiple signs of leakage and needs replacement; gas shutoff valves for furnace and water heater are seized shut and need replacement; basement laundry gas line is loose and needs a drip leg installed; leaky bib faucet in basement laundry is dripping onto the floor; hallway bathroom tub faucet, toilet, and cold water vanity faucet have been shut off.
- RoofArchitectural shingle roof estimated 1-2 years old is installed correctly and in satisfactory condition; ventilation, flashings, soffit, fascia, and gutters are satisfactory; loose aluminum soffit over porch needs to be tucked.
- WindowsKitchen sink window has one broken pane and one broken seal; both panes need replacement; minor damage observed to trim of other windows.
- HVACwater heater (2000, 50-gallon) has rust inside and suspected sediment buildup. further evaluation and possible replacement recommended. gas runs use rigid black steel pipe but shut-off valves are not hand-turnable, gas lines need securing and drip legs, though pressure test passed. condenser (2018, 3.5-ton) has fence restricting airflow and rusty capacitor with system pressure outside expected range. fence removal and capacitor replacement recommended. ductwork is rusty, dirty, inadequately sized, not sealed, and has missing/falling hangers
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedSewer
✓ documentedFoundation
✓ documentedElectrical
✓ documentedHVAC
✓ documentedPest
✓ documentedWindows
✓ documentedMold
undocumentedRadon
undocumentedAppraisals
undocumented