- HVAC · Indoor unit frozen over; evaporator fans replaced and system restored · Jun 2026
- HVAC · Hallway R22 unit failing on high pressure; replacement recommended · Jun 2026
- HVAC · Attic unit heater failed; bad element found, replacement needed · Dec 2025
- HVAC · Indoor unit and heat kit voltages verified for equipment order · Jul 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 4 documented records for 1333 South Scenic Drive, Herculaneum, MO 63048, dated from December 2025 through July 2026. The amount summary includes $2,280.28 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Attic heater bad element; needs replacement
- HVAC
Built from Housecall Pro data
- $259HVACService call for attic unit heater not functioning; found a bad heating element and, due to age and parts availability, the unit needs to be replaced.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — R22 unit high-pressure limit; replace system
- HVAC
Built from Housecall Pro data
- $324HVACService call for hallway system not cooling; found older R22 unit going out on high pressure due to a restriction in the coil, blowing 60 degree air when not on high limit, and recommended replacing the system.
- HVACPhotograph shows a large HVAC air handler/furnace cabinet installed in a mechanical room, with visible discoloration and staining on the top of the unit and surrounding ductwork; trilingual hazardous voltage warning labels and a copper-conductors-only notice are affixed to the cabinet face; a data plate is present at the lower portion of the unit.
- HVACPhotograph shows Fieldpiece app refrigerant side measurements: suction pressure 86.0 psig at 99.7°F and liquid pressure 428.3 psig at 97.8°F; vapor/liquid saturation, superheat, and subcooling are blank pending refrigerant type selection.
- HVACPhotograph shows the manufacturer data plate of a Trane Odyssey outdoor HVAC unit, Model No. TTA090A400GA, Serial No. 12325RLTYA, manufactured 8/2012, using R22 refrigerant, rated 460V/3PH/60Hz with 100 LRA, assembled in Mexico.
- HVACPhotograph shows interior of an HVAC air handler with a large pulley/sheave, a visibly worn and cracked drive belt, and a blower wheel with heavy dust and debris accumulation on the fins.
- HVACFieldpiece app refrigerant-side readings show suction pressure 108.7 psig / 98.5°F and liquid pressure 435.7 psig / 96.3°F; refrigerant type not selected so superheat and subcooling are not calculated.
- HVACPhotograph shows an outdoor HVAC condenser unit with heavily soiled condenser coil fins covered in white residue and accumulated grass/straw debris at the base; a disconnect box is mounted on the adjacent wall and a technician's tool bag with clamp meter rests on top of the unit.
- HVACPhotograph shows a white digital thermostat enclosed in a clear plastic tamper-resistant lockbox, displaying approximately 70°F current temperature and 70°F set point, with FAN and SYSTEM slide switches visible; brand partially legible as 'Whi... R...'.
- HVACPhotograph shows an outdoor HVAC condenser unit with condenser coil fins heavily fouled with dirt, debris, and organic matter; vegetation is growing directly against the base of the unit.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Repair Service — Frozen system; evaporator fans replaced
- HVAC
Built from Housecall Pro data
- $1,697HVACFound system frozen over and indoor evaporator fans faulty; replaced the fans, checked system charge, and all systems were working as intended.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Voltage Verification — Indoor unit and heat kit voltage verified
- HVAC
Built from Housecall Pro data
- HVACVerified indoor unit voltage and heat kit voltage for equipment order.