HVACCompleted work$324
Service call for hallway system not cooling; found older R22 unit going out on high pressure due to a restriction in the coil, blowing 60 degree air when not on high limit, and recommended replacing the system.
HVACWork status not resolved
Photograph shows a large HVAC air handler/furnace cabinet installed in a mechanical room, with visible discoloration and staining on the top of the unit and surrounding ductwork; trilingual hazardous voltage warning labels and a copper-conductors-only notice are affixed to the cabinet face; a data plate is present at the lower portion of the unit.
HVACWork status not resolved
Photograph shows Fieldpiece app refrigerant side measurements: suction pressure 86.0 psig at 99.7°F and liquid pressure 428.3 psig at 97.8°F; vapor/liquid saturation, superheat, and subcooling are blank pending refrigerant type selection.
HVACWork status not resolved
Photograph shows the manufacturer data plate of a Trane Odyssey outdoor HVAC unit, Model No. TTA090A400GA, Serial No. 12325RLTYA, manufactured 8/2012, using R22 refrigerant, rated 460V/3PH/60Hz with 100 LRA, assembled in Mexico.
HVACWork status not resolved
Photograph shows interior of an HVAC air handler with a large pulley/sheave, a visibly worn and cracked drive belt, and a blower wheel with heavy dust and debris accumulation on the fins.
HVACWork status not resolved
Fieldpiece app refrigerant-side readings show suction pressure 108.7 psig / 98.5°F and liquid pressure 435.7 psig / 96.3°F; refrigerant type not selected so superheat and subcooling are not calculated.
HVACWork status not resolved
Photograph shows an outdoor HVAC condenser unit with heavily soiled condenser coil fins covered in white residue and accumulated grass/straw debris at the base; a disconnect box is mounted on the adjacent wall and a technician's tool bag with clamp meter rests on top of the unit.
HVACWork status not resolved
Photograph shows a white digital thermostat enclosed in a clear plastic tamper-resistant lockbox, displaying approximately 70°F current temperature and 70°F set point, with FAN and SYSTEM slide switches visible; brand partially legible as 'Whi... R...'.
HVACWork status not resolved
HVACWork status not resolved
Photograph shows an outdoor HVAC condenser unit with condenser coil fins heavily fouled with dirt, debris, and organic matter; vegetation is growing directly against the base of the unit.