← MAP

1471 Wishart Avenue

Overland, MO 6313238.6862°N, 90.3794°W
4Events
Contributed by:1 contributor
$4.1kDocumented amounts
SOURCE-BACKED RECORDS

Across 4 records on this home

Completed work

Invoices and paid receipts

$2.4k

Estimated · not confirmed

Quotes, estimates, and other amounts not confirmed as performed

$1.7k

Property History Report

Negotiate this home like you've seen its receipts. You have.

Free right now · built from this home's 4 documented records

Fresh House Property Summary

Highlights selected from 4 documented records for this property.

  • HVAC
    HVAC · Evaporator coil replaced on the cooling system · Jun 2026
  • HVAC
    HVAC · Furnace control transformer replaced and rewired for cooling · Jul 2026
  • HVAC
    HVAC · Refrigerant charge added to the outdoor AC unit · Jun 2026
  • HVAC
    HVAC · Estimate on record for full AC replacement; not confirmed done · Jun 2026
Ask this homePowered by Fresh House property intelligence®
THE HOME

Hi, I'm 1471 Wishart Avenue. I only speak from this property's source-backed records — 4 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.

ASK ME ABOUT

RECORD SUMMARY

4 documented events
Contributed by: 1 contributor
First documented event: Jun 2026
Latest documented event: Jun 2026
First added to Fresh House: Nov 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 4 documented records for 1471 Wishart Avenue, Overland, MO 63132, dated in June 2026. The amount summary includes $2,398 in completed work across HVAC, $1,675 in estimates; appraisal values and permit-declared valuations are excluded.

HVAC

HVAC Refrigerant Service — Refrigerant charge added (410, 3 lbs max)

Document dated Jun 24, 2026Uploaded Nov 8, 20267 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 1471 Wishart Avenue, Overland, MO 63132.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $554
  • HVACDiagnostic trip performed and refrigerant charge (410, 3 lbs max) added.
    $554
  • HVACPhotograph shows a Rheem outdoor condensing unit data plate: Model RA1342AJ1NA, Serial W211529578, manufactured 05/2015, R410A refrigerant, 208/230V single-phase, assembled in Mexico.
  • HVACPhotograph shows a Rheem gas furnace data plate (Model R801SA125524MSA, Serial W481432310, manufactured 12/2014) rated at 125,000 BTU/hr maximum input, configured for natural gas.
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC
Attached photo 4HVAC
+2

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Replacement Estimate — 3.5-ton A/C and coil replacement option

Document dated Jun 24, 2026Uploaded Nov 8, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 1471 Wishart Avenue, Overland, MO 63132.
Scope
  • HVAC
Contributor
worked on or inspected it

Options: Option #1 $1,675 · Basic 14 SEER 3.5-ton Air Conditioner and Evaporator Coil $7,580 (all expired)

Built from Housecall Pro data

Estimated value on this timeline entry: $1,675
  • HVACEstimate for two options: evaporator coil replacement, or a 3.5-ton 14 SEER air conditioner with American Standard cased evaporator coil, condenser pad, 30-amp disconnect, materials and labor.
    $1,675

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Evaporator Coil Replacement — 4-ton evaporator coil replaced

Document dated Jun 29, 2026Uploaded Nov 8, 20266 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 1471 Wishart Avenue, Overland, MO 63132.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $1,210
  • HVACReplaced evaporator coil, 4-ton with 410A, at the service address.
    $1,210
  • HVACPhotograph shows an open HVAC air handler cabinet with an A-frame evaporator coil exhibiting heavy reddish-brown corrosion/oxidation on the copper tubing and fin surfaces; refrigerant lines, service port caps, and handwritten markings '2114' and '-4-' are visible on the back panel.
  • HVACPhotograph shows a Testo 557 digital manifold gauge connected to an R410A system, displaying low-side pressure of 130.1 psi with 15.6°F superheat and high-side pressure of 395.4 psi with 4.4°F subcooling.
warranty1-yearFrom invoiceView details
Documented warrantyfrom invoice · Jun 29, 2026HVAC · 1 term

What this warranty covers

1-year
  • evaporator
    · source

    “1-year parts and labor warranty on evaporator only.”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC
Attached photo 4HVAC
+1

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Repair — Replaced 40 VA control transformer

Document dated Jul 17, 2026Uploaded Nov 8, 202612 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 1471 Wishart Avenue, Overland, MO 63132.
Scope
  • HVAC
Outcome
Paid in full

Built from Housecall Pro data

Total documented value on this timeline entry: $634
  • HVACPerformed a residential diagnostic service, replaced the 40 VA control transformer, and rewired the furnace to allow for cooling (no heat).
    $634
  • HVACPhotograph shows the interior wiring compartment of an HVAC air handler with a White-Rodgers control board; multiple colored wires are bundled in a disorganized manner and heavy dust accumulation is visible on the control board, transformer, and wiring throughout the compartment.
  • HVACPhotograph shows a worn metal data plate on a natural gas furnace, displaying model No. P1CKD12N06401A, serial No. EHEM356419, 1/2 HP motor, 180°F max outlet air temperature, gas supply pressure max 10.5" / min 4.5" W.C., manifold pressure 3.5" W.C., and input BTU/HR of 64,000; surrounding cabinet shows significant rust and age.
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC
Attached photo 4HVAC
+7

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

HVAC
✓ documented
Home Inspection
undocumented
Roof
undocumented
Plumbing
undocumented
Sewer
undocumented
Foundation
undocumented
Mold
undocumented
Electrical
undocumented
Pest
undocumented
Radon
undocumented
Appraisals
undocumented
Windows
undocumented

Nearby homes with documented history