Hi, I'm 1471 Wishart Avenue. I only speak from this property's source-backed records — 4 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
1471 Wishart Avenue
Across 4 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 4 documented records
Fresh House Property Summary
Highlights selected from 4 documented records for this property.
- HVAC · Evaporator coil replaced on the cooling system · Jun 2026
- HVAC · Furnace control transformer replaced and rewired for cooling · Jul 2026
- HVAC · Refrigerant charge added to the outdoor AC unit · Jun 2026
- HVAC · Estimate on record for full AC replacement; not confirmed done · Jun 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 4 documented records for 1471 Wishart Avenue, Overland, MO 63132, dated in June 2026. The amount summary includes $2,398 in completed work across HVAC, $1,675 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Refrigerant Service — Refrigerant charge added (410, 3 lbs max)
- HVAC
Built from Housecall Pro data
- $554HVACDiagnostic trip performed and refrigerant charge (410, 3 lbs max) added.
- HVACPhotograph shows a Rheem outdoor condensing unit data plate: Model RA1342AJ1NA, Serial W211529578, manufactured 05/2015, R410A refrigerant, 208/230V single-phase, assembled in Mexico.
- HVACPhotograph shows a Rheem gas furnace data plate (Model R801SA125524MSA, Serial W481432310, manufactured 12/2014) rated at 125,000 BTU/hr maximum input, configured for natural gas.
- HVACPhotograph shows a 16x25x1 pleated air filter removed from HVAC ductwork; filter media appears visibly dirty/dusty, indicating it is due for replacement.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an outdoor condenser unit, displaying R410A refrigerant readings: low-side 79.8 psi (superheat 50.2°F) and high-side 259.2 psi (subcooling 4.5°F).
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an outdoor condenser unit, displaying R410A refrigerant readings: evaporator saturation temperature 20.6°F, condenser saturation temperature 85.9°F, low-side pressure 79.6 psi, and high-side pressure 259.2 psi.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Replacement Estimate — 3.5-ton A/C and coil replacement option
- HVAC
Options: Option #1 $1,675 · Basic 14 SEER 3.5-ton Air Conditioner and Evaporator Coil $7,580 (all expired)
Built from Housecall Pro data
- $1,675HVACEstimate for two options: evaporator coil replacement, or a 3.5-ton 14 SEER air conditioner with American Standard cased evaporator coil, condenser pad, 30-amp disconnect, materials and labor.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Evaporator Coil Replacement — 4-ton evaporator coil replaced
- HVAC
Built from Housecall Pro data
- $1,210HVACReplaced evaporator coil, 4-ton with 410A, at the service address.
- HVACPhotograph shows an open HVAC air handler cabinet with an A-frame evaporator coil exhibiting heavy reddish-brown corrosion/oxidation on the copper tubing and fin surfaces; refrigerant lines, service port caps, and handwritten markings '2114' and '-4-' are visible on the back panel.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an R410A system, displaying low-side pressure of 130.1 psi with 15.6°F superheat and high-side pressure of 395.4 psi with 4.4°F subcooling.
- HVACa small cylindrical filter/drier canister is visible on the left side of the unit
- HVACPhotograph shows a gray louvered foundation/crawl space vent with multiple spider webs strung across the vent openings; dark soil and dry debris are visible through the slats.
Documented warranty1-yearFrom invoiceView details
What this warranty covers
- evaporator
· source
“1-year parts and labor warranty on evaporator only.”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Repair — Replaced 40 VA control transformer
- HVAC
Built from Housecall Pro data
- $634HVACPerformed a residential diagnostic service, replaced the 40 VA control transformer, and rewired the furnace to allow for cooling (no heat).
- HVACPhotograph shows the interior wiring compartment of an HVAC air handler with a White-Rodgers control board; multiple colored wires are bundled in a disorganized manner and heavy dust accumulation is visible on the control board, transformer, and wiring throughout the compartment.
- HVACPhotograph shows a worn metal data plate on a natural gas furnace, displaying model No. P1CKD12N06401A, serial No. EHEM356419, 1/2 HP motor, 180°F max outlet air temperature, gas supply pressure max 10.5" / min 4.5" W.C., manifold pressure 3.5" W.C., and input BTU/HR of 64,000; surrounding cabinet shows significant rust and age.
- HVAC10AJB24A01, Serial No. 6932 T1505 05380, manufactured 04/2005) using R22 refrigerant with 208/230V single-phase power
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an R22 refrigerant system, displaying low-side pressure of 71.8 psi and high-side pressure of 248.3 psi, with temperature readings of approximately 116.5°F and 118.0°F.
- HVACPhotograph shows a wall cavity with numerous disorganized wires of multiple colors (tan, red, black, blue) running loosely without conduit, along with a small white wire connector/lug with a set screw visible at the center, mounted on what appears to be a metal stud track.
- HVACPhotograph shows a True RMS 400A AC/DC digital clamp meter displaying a reading of 08.47 amperes.
- HVACPF42440) with primary voltage 120/208/240V, secondary voltage 24V, 40 VA output, foot mounting, and wire lead connection
- HVACthe surrounding floor shows heavy staining and deterioration
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.