Record 1Public property record

HVAC Refrigerant Service — Refrigerant charge added (410, 3 lbs max)

  • HVAC

On June 24, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1471 Wishart Avenue, Overland, MO 63132.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$554

    Diagnostic trip performed and refrigerant charge (410, 3 lbs max) added.

  • HVACWork status not resolved

    Photograph shows a Rheem outdoor condensing unit data plate: Model RA1342AJ1NA, Serial W211529578, manufactured 05/2015, R410A refrigerant, 208/230V single-phase, assembled in Mexico.

  • HVACWork status not resolved

    Photograph shows a Rheem gas furnace data plate (Model R801SA125524MSA, Serial W481432310, manufactured 12/2014) rated at 125,000 BTU/hr maximum input, configured for natural gas.

  • HVACWork status not resolved

    Photograph shows a 16x25x1 pleated air filter removed from HVAC ductwork; filter media appears visibly dirty/dusty, indicating it is due for replacement.

  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge connected to an outdoor condenser unit, displaying R410A refrigerant readings: low-side 79.8 psi (superheat 50.2°F) and high-side 259.2 psi (subcooling 4.5°F).

  • HVACWork status not resolved
  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge connected to an outdoor condenser unit, displaying R410A refrigerant readings: evaporator saturation temperature 20.6°F, condenser saturation temperature 85.9°F, low-side pressure 79.6 psi, and high-side pressure 259.2 psi.

Record 2Public property record

HVAC Replacement Estimate — 3.5-ton A/C and coil replacement option

  • HVAC

On June 24, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1471 Wishart Avenue, Overland, MO 63132.

Record date

Available findings

  • HVACEstimate or proposed work$1,675

    Estimate for two options: evaporator coil replacement, or a 3.5-ton 14 SEER air conditioner with American Standard cased evaporator coil, condenser pad, 30-amp disconnect, materials and labor.

Record 3Public property record

HVAC Evaporator Coil Replacement — 4-ton evaporator coil replaced

  • HVAC

On June 29, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1471 Wishart Avenue, Overland, MO 63132.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$1,210

    Replaced evaporator coil, 4-ton with 410A, at the service address.

  • HVACWork status not resolved

    Photograph shows an open HVAC air handler cabinet with an A-frame evaporator coil exhibiting heavy reddish-brown corrosion/oxidation on the copper tubing and fin surfaces; refrigerant lines, service port caps, and handwritten markings '2114' and '-4-' are visible on the back panel.

  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge connected to an R410A system, displaying low-side pressure of 130.1 psi with 15.6°F superheat and high-side pressure of 395.4 psi with 4.4°F subcooling.

  • HVACWork status not resolved

    a small cylindrical filter/drier canister is visible on the left side of the unit

  • HVACWork status not resolved
  • HVACWork status not resolved

    Photograph shows a gray louvered foundation/crawl space vent with multiple spider webs strung across the vent openings; dark soil and dry debris are visible through the slats.

Record 4Public property record

HVAC Repair — Replaced 40 VA control transformer

  • HVAC

On July 17, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1471 Wishart Avenue, Overland, MO 63132.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$634

    Performed a residential diagnostic service, replaced the 40 VA control transformer, and rewired the furnace to allow for cooling (no heat).

  • HVACWork status not resolved

    Photograph shows the interior wiring compartment of an HVAC air handler with a White-Rodgers control board; multiple colored wires are bundled in a disorganized manner and heavy dust accumulation is visible on the control board, transformer, and wiring throughout the compartment.

  • HVACWork status not resolved

    Photograph shows a worn metal data plate on a natural gas furnace, displaying model No. P1CKD12N06401A, serial No. EHEM356419, 1/2 HP motor, 180°F max outlet air temperature, gas supply pressure max 10.5" / min 4.5" W.C., manifold pressure 3.5" W.C., and input BTU/HR of 64,000; surrounding cabinet shows significant rust and age.

  • HVACWork status not resolved

    10AJB24A01, Serial No. 6932 T1505 05380, manufactured 04/2005) using R22 refrigerant with 208/230V single-phase power

  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge connected to an R22 refrigerant system, displaying low-side pressure of 71.8 psi and high-side pressure of 248.3 psi, with temperature readings of approximately 116.5°F and 118.0°F.

  • HVACWork status not resolved

    Photograph shows a wall cavity with numerous disorganized wires of multiple colors (tan, red, black, blue) running loosely without conduit, along with a small white wire connector/lug with a set screw visible at the center, mounted on what appears to be a metal stud track.

  • HVACWork status not resolved

    Photograph shows a True RMS 400A AC/DC digital clamp meter displaying a reading of 08.47 amperes.

  • HVACWork status not resolved
  • HVACWork status not resolved

    PF42440) with primary voltage 120/208/240V, secondary voltage 24V, 40 VA output, foot mounting, and wire lead connection

  • HVACWork status not resolved

    the surrounding floor shows heavy staining and deterioration