Hi, I'm 1501 Quendo Avenue. I only speak from this property's source-backed records — 4 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
1501 Quendo Avenue
Across 4 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 4 documented records
Fresh House Property Summary
Highlights selected from 4 documented records for this property.
- HVAC · Full HVAC system replaced with new furnace and AC · Jan 2021$6.2k
- HVAC · Gas valve replaced and pilot lines repaired on furnace and water heater · Dec 2020
- HVAC · Thermostat replaced after heat would not shut off · Dec 2020
- HVAC · Fan and demand controls adjusted to fix cycling issue · Nov 2020
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 4 documented records for 1501 Quendo Avenue, St. Louis, MO 63130, dated from November 2020 through December 2020. The amount summary includes $7,109.08 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Adjusted fan and demand controls; cycling fixed
- HVAC
Built from Housecall Pro data
- $154HVACService call; found system not cycling properly, adjusted fan controls and system demand controls, and ran system through two cycles to confirm it worked properly.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Repair — Repaired the pilot feeder tube to the water
- HVAC
Built from Housecall Pro data
- $440HVACRepaired the pilot feeder tube to the water heater, assembled a new pilot gas valve and fuel run for the furnace with flare fittings in place of the cracked valve, and leak checked the system with no other leaks found.
- HVACPhotograph shows a heavily corroded brass/bronze valve assembly with green and blue-green verdigris corrosion on the valve body and fittings, visible moisture pooling and blue-green mineral staining on the surface below, indicating an active or recent water leak at the valve connections.
- HVACPhotograph shows a brass ball valve (shutoff valve) with compression fittings accessed through a cutout opening in a wall panel, surrounded by heavy corrosion, rust staining, debris, and deteriorated masonry or concrete at the base.
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Thermostat Replacement — Thermostat replaced; heat won't shut
- HVAC
Built from Housecall Pro data
- $274HVACInspected the system for a heat that wouldn't shut off, found no failing components, and replaced the thermostat with an Emerson 80 series non-programmable thermostat.
- HVACPhotograph shows a white Emerson digital thermostat mounted on an interior wall, with the LCD display reading approximately 52°F current temperature and 53°F set point.
- HVACPhotograph shows interior of a furnace or boiler with heavy rust and corrosion on metal panels and housing, two small blue glowing points visible through openings consistent with pilot lights or igniters, and wiring visible in the lower compartment; significant deterioration of metal components is evident.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Replacement — Rheem 80% furnace + 2.5-ton 13 SEER A/C
- HVAC
Built from Housecall Pro data
- $6,241HVACWork performed: Full System 13 Seer 80% AFUE - 2.5 Ton 13 Seer, 80% Value Series Furnace 75,000 BTU, TXV cased Coil (We propose to install the following equipment in your home: Sure Comfort By); Install Desc - Install Description Full 80% (This quote will include the following, fused disconnect, whip and pad for the); Install Desc - Equipment Warranty.
- HVACPhotograph shows a high-efficiency gas furnace installed in a basement utility area, with flexible stainless flue pipe, sheet metal ductwork above, black iron gas supply piping on the right, and an EnergyGuide label affixed to the unit
- HVACPhotograph shows a basement mechanical room with a large gray vertical air handler unit connected to a sheet-metal supply plenum above, copper refrigerant lines running along the ceiling, and associated piping and wiring visible in an unfinished basement space.
- HVACPhotograph shows a gray furnace unit with copper flue piping at the top, positioned adjacent to a large sheet metal duct plenum in what appears to be a basement utility space; electrical wiring and flexible conduit are visible on the unit.
Documented warranty5 year / 10 year / 20 year / one yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed comes with a 5 year parts warranty”
- Labor
· source
“We do offer a 5 year Labor warranty for an additional $500”
- compressor
· source
“10 year compressor warranty”
- parts/compressor
· source
“Once equipment is registered this will become 10 year parts/compressor warranty”
- heat exchanger
· source
“20 year heat exchanger warranty”
- labor
· source
“We offer a one year labor warranty at no additional cost.”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.