Hi, I'm 1417 Anna Avenue. I only speak from this property's source-backed records — 2 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
← MAPSOURCE-BACKED RECORDS
1417 Anna Avenue
University City, MO 6313038.6759°N, 90.3302°W
2Events
Contributed by:1 contributor

Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 2 documented records
Fresh House Property Summary
Highlights selected from 2 documented records for this property.
- Radon · Basement radon test returned 4.1 pCi/L; EPA mitigation level reached · Sep 2026
Ask this homePowered by Fresh House property intelligence®
ASK ME ABOUT
RECORD SUMMARY
2 documented events
Contributed by: 1 contributor
First documented event: Sep 2026
Latest documented event: Sep 2026
First added to Fresh House: Sep 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
This page contains 2 documented records for 1417 Anna Avenue, University City, MO 63130, dated in September 2026.
Home Inspection
Home Inspection Document
Inspected Sep 9, 2026Uploaded Sep 14, 20262 files
Documented from uploaded report
Property Professional Uploaded
By
Greensmith Home Inspection llcdocumented Electrical, Foundation, HVAC, and 6 other topics at 1417 Anna Avenue, University City, MO 63130.
Scope
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Plumbing,
- Radon,
- Roof,
- Sewer,
- Windows
Contributor
worked on or inspected it- Home InspectionWhole-home inspection of single-family property found no structural issues overall, but identified multiple deficiencies including tree root blockage in sewer lateral, stone foundation cracks, inoperable garage door opener, missing smoke detectors, disconnected basement toilet, and broken window pane.
- Electricalsmoke detectors are missing throughout the home and need to be installed some outlets are 2-prong ungrounded and some are loose from the wall
- FoundationStone foundation has cracks and missing mortar on exterior and basement walls; inspector recommends sealing cracks, replacing missing mortar, removing spalling, and coating affected areas with Drylok or similar waterproofing product.
- HVACsecondary system includes window AC and baseboard heat on second floor
- Plumbingbasement bathroom toilet is disconnected and likely needs replacement hallway bathroom toilet valve needs adjustment
- RoofArchitectural shingle roof (front-facing shingles ~3 years old, remaining ~15 years old showing wear but performing properly); deficiencies include tree limbs contacting structure and a bunched group of shingles on the front left dormer needing straightening.
- SewerScaling present on inside of cast-iron drain lines and tree roots found in the clay section of the pipe at approximately 77 ft forming a blockage; hydroflushing recommended for proper flow.
- WindowsOne broken window pane in the basement needs replacement, minor damage around the entryway window needs repair, and one dining room window will not stay open and needs window balances adjusted.
- Radon48-hour radon test in basement of 1417 Anna Ave, St. Louis, MO returned an EPA protocol average of 4.1 pCi/L, meeting or exceeding the EPA action level of 4 pCi/L; mitigation is recommended.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Home Inspection
Home Inspection Document
Inspected Sep 9, 2026Uploaded Sep 9, 20263 files
Documented from uploaded report
Property Professional Uploaded
By
Greensmith Home Inspection llcdocumented Electrical, Foundation, HVAC, and 6 other topics at 1417 Anna Avenue, University City, MO 63130.
Scope
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Sewer,
- Windows
Contributor
worked on or inspected it- Home InspectionWhole-home inspection of single-family property found the home in generally good condition with no structural issues; deficiencies noted across roofing, foundation, plumbing, electrical, and windows requiring attention.
- Electricalsmoke detectors are missing throughout the home and must be installed 2-prong ungrounded outlets present garage door opener is inoperable from the wall switch and needs repair or replacement
- FoundationStone foundation has cracks and missing mortar requiring sealing and repointing; basement walls show common cracks and spalling and should be coated with Drylok or similar waterproofing product.
- HVACHVAC system operating properly secondary system includes window AC and baseboard heat on second floor
- PlumbingTree roots present in the clay section of the waste pipe forming a blockage with scaling inside cast-iron lines; hydroflushing recommended; water heater (GE, 50-gal electric, mfgd 2009) functional; basement toilet disconnected and likely needs replacement.
- RoofArchitectural shingle roof (estimated 3; 15 years old) is performing properly; deficiencies include tree limbs contacting the structure and a bunched group of shingles on the front left dormer needing straightening.
- WindowsOne broken window pane in the basement requires replacement and minor damage around the entryway window needs repair; one dining room window will not stay open and needs window balances adjusted.
- SewerSewer lateral inspection found scaling inside the cast-iron portion and tree root intrusion into the clay portion forming a blockage; hydroflushing recommended for proper flow.
- Pestno action or treatment recommended
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedSewer
✓ documentedFoundation
✓ documentedElectrical
✓ documentedHVAC
✓ documentedPest
✓ documentedRadon
✓ documentedWindows
✓ documentedMold
undocumentedAppraisals
undocumented