Record 1Public property record

Document (07/09/2026)

  • Electrical
  • Foundation
  • HVAC
  • Home Inspection
  • Pest
  • Plumbing
  • Roof
  • Sewer
  • Windows

On July 8, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 6 other topics at 155 Saint Maurice Lane, Florissant, MO 63031.

Record date

Available findings

  • PestWork status not resolved

    Visual WDI inspection of SFR/Attached Carport at 155 Saint Maurice Lane found no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or reinfesting wood boring beetles); no treatment recommended.

  • Home InspectionWork status not resolved

    Whole-home inspection of single-family property identified deficiencies including a non-GFCI exterior outlet, window caulking needed, furnace requiring cleaning/servicing, and heavy tree root intrusion in the clay sewer lateral; no structural issues observed.

  • ElectricalWork status not resolved

    Rear exterior outlet is functional but needs replacement with a GFCI-protected plug; 2-prong ungrounded outlets also present throughout interior; Cutler Hammer 100-amp service panel in basement appears functional.

  • HVACWork status not resolved

    Central split system performing properly; Carrier gas furnace (54,000 BTU, mfgd 2012) needs cleaned and serviced; Lennox 3-ton AC condenser (mfgd 2024) functioning correctly.

  • PlumbingWork status not resolved

    State natural gas water heater (40 gal, mfgd 2000) appears functional but is aged; copper supply pipes satisfactory; waste pipes are PVC, cast iron, and clay.

  • SewerWork status not resolved

    Heavy tree root intrusion observed in the clay section of the sewer lateral lines from minor offsets at joints; hydro-flushing and chemical root-killing foam recommended; liners may be needed in affected areas in the future.

  • RoofWork status not resolved

    Architectural shingle roof covering is approximately 1 year old and installed correctly; gable design with metal flashings, aluminum soffit/fascia, and metal gutters all satisfactory; drone inspection method used.

  • WindowsWork status not resolved

    Vinyl and glass block windows are satisfactory overall; caulking around window exteriors is needed in several locations.

  • FoundationWork status not resolved

    Poured concrete foundation with basement and crawl space is satisfactory; basement floor is fully finished but missing vinyl square tiles; crawl space vapor retarder installed and satisfactory; no moisture detected.