155 Saint Maurice Lane
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- Electrical · Exterior outlet lacks GFCI protection; ungrounded outlets found inside · 2026
- HVAC · Furnace needs cleaning and servicing · 2026
- Sewer · Heavy tree root intrusion found in clay sewer lateral · 2026
- Plumbing · Water heater is aged and may need replacement soon · 2026
- Roof · Roof covering is approximately one year old and in good condition · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 155 Saint Maurice Lane, Florissant, MO 63031, dated in July 2026.
Home Inspection Document
On July 8, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 6 other topics at 155 Saint Maurice Lane, Florissant, MO 63031.
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Sewer,
- Windows
- Home InspectionWhole-home inspection of single-family property identified deficiencies including a non-GFCI exterior outlet, window caulking needed, furnace requiring cleaning/servicing, and heavy tree root intrusion in the clay sewer lateral; no structural issues observed.
- PestVisual WDI inspection of SFR/Attached Carport at 155 Saint Maurice Lane found no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or reinfesting wood boring beetles); no treatment recommended.
- ElectricalRear exterior outlet is functional but needs replacement with a GFCI-protected plug; 2-prong ungrounded outlets also present throughout interior; Cutler Hammer 100-amp service panel in basement appears functional.
- HVACCentral split system performing properly; Carrier gas furnace (54,000 BTU, mfgd 2012) needs cleaned and serviced; Lennox 3-ton AC condenser (mfgd 2024) functioning correctly.
- PlumbingState natural gas water heater (40 gal, mfgd 2000) appears functional but is aged; copper supply pipes satisfactory; waste pipes are PVC, cast iron, and clay.
- SewerHeavy tree root intrusion observed in the clay section of the sewer lateral lines from minor offsets at joints; hydro-flushing and chemical root-killing foam recommended; liners may be needed in affected areas in the future.
- RoofArchitectural shingle roof covering is approximately 1 year old and installed correctly; gable design with metal flashings, aluminum soffit/fascia, and metal gutters all satisfactory; drone inspection method used.
- WindowsVinyl and glass block windows are satisfactory overall; caulking around window exteriors is needed in several locations.
- FoundationPoured concrete foundation with basement and crawl space is satisfactory; basement floor is fully finished but missing vinyl square tiles; crawl space vapor retarder installed and satisfactory; no moisture detected.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,