Hi, I'm 105 Dunn Road. I only speak from this property's source-backed records — 3 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
105 Dunn Road
Across 3 records on this property
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Fresh House Property Summary
Highlights selected from 3 documented records for this property.
- HVAC · Refrigerant charge added to commercial HVAC system · Jul 2026
- HVAC · Commercial HVAC diagnostic service and return trip performed · Jul 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 3 documented records for 105 Dunn Road, Florissant, MO 63031, dated in July 2026. The amount summary includes $1,670.50 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Refrigerant Service — Refrigerant charge added (410, 3 lbs max)
- HVAC
Built from Housecall Pro data
- $912HVACAdded refrigerant charge (410, up to 3 lbs max) with after-hours commercial maintenance labor billed at 2.5 hours of 410-A labor.
- HVACPhotograph shows a CPS digital refrigerant scale (model #T6-141) displaying a reading of -2 lbs 6.00 oz, with a coiled cable attached, resting on a light-colored surface.
- HVACPhotograph shows a rooftop HVAC condensing unit with refrigerant service hoses (red and blue) and a digital manifold gauge set connected to service ports; insulated suction and liquid lines run to a secondary air handler unit, with visible frost/ice on the suction line near the condenser; a vacuum pump with yellow hose and technician tool bag with cordless drill are also present.
- HVACPhotograph shows a Testo 557 digital manifold gauge displaying R-410A refrigerant readings: left side shows approximately 40.6°F superheat (SH) and 148.1 psi, right side shows approximately 44°F subcooling (SC) and 413.9 psi.
- HVACPhotograph shows a Testo 557 digital manifold gauge set connected to an HVAC system, displaying R410A refrigerant readings: low-side pressure 155.6 psi with superheat of 24.1°F, and high-side pressure 475.7 psi with subcooling of 9.5°F.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an HVAC system, displaying R410A refrigerant readings: low-side 22.3 psig / 21.8°F saturation and high-side 349.2 psig / 128.6°F saturation.
- HVACthe thermostat housing and surrounding wall show visible dirt and grime accumulation
- HVACa second note requests keeping heat/cool at a comfortable level for occupants and merchandise
- HVACPhotograph shows a Testo 557 digital manifold gauge displaying R410A refrigerant readings: T1 = 92.6°F, T2 = 115.4°F, high-side pressure = 148.8 psi, low-side pressure = 41.25 psi.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge HVAC service visit
- HVAC
Built from Housecall Pro data
- HVACPhotograph shows a yellow SPK2 handheld digital thermometer with its probe inserted into a light-colored metal panel (consistent with an HVAC unit casing), displaying a reading of 78.6°F.
- HVACPhotograph shows a handheld SPK2 digital thermometer displaying a reading of 63.5°F, held against what appears to be an HVAC unit or metal panel surface with dark staining visible along a seam in the background.
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Service — Commercial diagnostic, labor
- HVAC
Built from Housecall Pro data
- $759HVACCommercial HVAC diagnostic service and return trip performed with 2 hours of commercial labor, and 404-A refrigerant supplied.
- HVACPhotograph shows a blue HVAC/refrigeration control board mounted in a metal enclosure, with an illuminated red LED display (possibly showing an error or status code), multiple wired terminal connections, a capacitor, and labeled inputs for room temp, defrost temp, suction temp, suction pressure, and outdoor temp.
- HVACPhotograph shows an HVAC coil (condenser or evaporator) with fins heavily coated in dust, dirt, and debris accumulation across the entire visible surface, indicating significant restriction to airflow.
- HVACPhotograph shows the condenser coil fins of an outdoor HVAC unit heavily fouled with accumulated dirt, dust, and debris across the entire coil surface, with the unit mounted on metal support rails above a concrete pad.
- HVACPhotograph shows multiple electrical cables routed across a flat roof membrane, converging at a heavily corroded/tar-coated conduit stub with a deteriorated weatherproof connector and a cable clamp; visible corrosion and rust are present on the fittings.
- UnclassifiedPhotograph shows a storage room interior with metal shelving, red plastic baskets, cardboard boxes, a vertical black pipe along the wall, and a missing/displaced ceiling tile revealing a dark open void above; a handwritten sign reading 'Please Not open' is visible on a wall panel or door.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,