Hi, I'm 1717 Fenpark Drive. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
1717 Fenpark Drive
Across 1 record on this property
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- HVAC · Non-programmable thermostat installed and refrigerant added · Aug 2026
- HVAC · Rooftop package unit (RTU-9) present at the property · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 1717 Fenpark Drive, Fenton, MO 63026, dated in August 2026. The amount summary includes $739 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Thermostat installed, 4 lbs 410-A added
- HVAC
Built from Housecall Pro data
- $739HVACInstalled a non-programmable thermostat and added 4 lbs of 410-A refrigerant, with trip fee and commercial labor.
- HVACPhotograph shows a CPS digital refrigerant scale displaying approximately 3.75 lbs on its LCD screen, alongside a yellow refrigerant charging hose and an HVAC component housing on a concrete surface.
- HVACPhotograph shows a CPS digital refrigerant scale on a concrete surface displaying a reading of 2 lbs 11.50 oz, with an HVAC condenser unit base visible nearby.
- HVACPhotograph shows the interior of an open HVAC unit with copper refrigerant lines, a brass valve fitting, multi-colored electrical wiring, and a coil assembly with visibly rusted and corroded fins and frame; pink barcode service tags are attached to components.
- HVACPhotograph shows the interior of an HVAC unit with a heavily corroded/rusted evaporator coil fin array, discolored copper refrigerant lines, a thermostatic expansion valve (TXV), wiring harnesses, and service tags attached to the coil and components.
- HVACPhotograph shows interior of an HVAC unit with a copper refrigerant line exhibiting heavy green corrosion (verdigris) at a brass fitting/joint, a pressure switch or sensor labeled PS1M4401, a contactor with multiple wiring terminals, a circuit board, and numerous multi-colored control wires.
- HVACPhotograph shows a Cooper 4005I Digital Thermometer clamped around a pipe on HVAC equipment, displaying a reading of 99°F; an HVAC control board with multicolored wiring and a brass fitting are visible in the background.
- HVACPhotograph shows a rooftop HVAC unit condensate drain stub-out (labeled 'CONDENSATE DRAIN CONNECTION') terminating at the roof surface with no piped connection to a drain, resulting in visible moisture staining, dark debris accumulation, and rust/corrosion on the unit curb below the discharge point.
- HVACmodel KGB036S4EY3P, serial 5620B07698, CAT# CW110, 36,000 BTU cooling, SEER 14, EER 12.3, 100,000 BTU max heating input, assembled in the USA, contains HFC-410A refrigerant
- HVACPhotograph shows a Yellow Jacket Test and Charging Manifold (Date Code 2019) with blue low-side and red high-side gauges calibrated for R-404, R-410, and R-22 refrigerants, connected via service hoses during HVAC refrigerant servicing.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,