Hi, I'm 538 Rudder Road. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
538 Rudder Road
Across 1 record on this property
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- HVAC · Commercial HVAC diagnostic service performed with new filters installed · Jul 2026
- HVAC · Rooftop condenser coil faces show accumulated debris and surface deposits · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 538 Rudder Road, Fenton, MO 63026. The amount summary includes $320 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Diagnostic Service — Commercial diagnostic service
- HVAC
Built from Housecall Pro data
- $320HVACPerformed commercial diagnostic service with commercial labor and supplied two 16/25/1 Merv 7 pleated filters.
- HVACPhotograph shows two ProPleat MERV 10, 16x20x2 pleated air filters installed side-by-side in an HVAC filter rack; surrounding housing shows dust/debris accumulation along the top edge.
- HVACPhotograph shows the base corner of a large white HVAC unit with significant rust and orange-brown staining along the bottom panel edges and around a black elbow condensate drain pipe, with visible deterioration of the surrounding roofing membrane.
- HVACPhotograph shows a rooftop HVAC unit with condenser coil fins heavily fouled with dirt and debris deposits across the entire coil face; fan grille shows rust discoloration and unit cabinet has surface rust at fastener points.
- HVACPhotograph shows a rooftop condenser unit with the condenser coil face heavily fouled with white/gray debris, dirt, and scale buildup across the entire coil surface; rust/corrosion is visible at the base of the coil panel, and a disconnect box with ON/OFF switch is mounted on the right side of the unit.
- HVACPhotograph shows a 3-pole electrical contactor mounted inside an enclosure, with red insulated wires connected to the upper terminals and yellow-tipped wires at the lower terminals; additional red, yellow, and gray conductors are visible in the surrounding area.
- HVACthe label is heavily soiled and partially peeling
- HVACPhotograph shows Fieldpiece app air-side measurements: return dry bulb 79.3°F / wet bulb 68.8°F / RH 58.5% / dew point 63.4°F / enthalpy 32.9 Btu/lbm; supply dry bulb 62.4°F / wet bulb 59.9°F / RH 86.4% / dew point 58.3°F / enthalpy 26.3 Btu/lbm; Delta T 16.9°F; refrigerant side suction and liquid pressures not linked.
- HVACPhotograph shows a 3-pole electrical contactor with yellow-insulated wire lugs connecting multiple red conductors on both the line and load sides, housed within an electrical enclosure
- HVACFieldpiece app psychrometric measurements show return air dry bulb 79.3°F, wet bulb 68.7°F, RH 58.5%, enthalpy 32.9 Btu/lbm and supply air dry bulb 62.5°F, wet bulb 59.9°F, RH 86.4%, enthalpy 26.4 Btu/lbm, with a Delta T of 16.8°F.
- HVACPhotograph shows three HVAC air filters with cardboard frames laid on a concrete surface; all three filter media panels are heavily darkened with accumulated dust and debris, indicating significant soiling and likely need for replacement.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.