Hi, I'm 1980 Centurion Drive. I only speak from this property's source-backed records — 2 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
1980 Centurion Drive
Across 2 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 2 documented records
Fresh House Property Summary
Highlights selected from 2 documented records for this property.
- HVAC · HVAC diagnostic performed and new thermostat installed · Jul 2026
- HVAC · Heater-not-heating complaint submitted; outcome not confirmed · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 1980 Centurion Drive, Fenton, MO 63026, dated from July 2026 through October 2026. The amount summary includes $349 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Thermostat Installation — Non-programmable thermostat installed
- HVAC
Built from Housecall Pro data
- $349HVACPerformed a residential diagnostic service and installed a non-programmable thermostat.
- HVACPhotograph shows the interior of a furnace with multiple heavily dust-coated and discolored wiring bundles zip-tied together, visible active blue burner flames in the background, and significant rust and debris accumulation on metal components.
- HVACfan is set to Auto and mode is set to Cool
- HVACFieldpiece app shows live R-410A refrigerant measurements: suction pressure 141.0 psig, liquid pressure 346.4 psig, actual superheat 17.2°F, actual subcooling 13.9°F, and Delta T 17.7°F.
- HVACFieldpiece app air-side measurements show return dry bulb 82.1°F / wet bulb 71.7°F / RH 60.5% and supply dry bulb 64.5°F / wet bulb 61.4°F / RH 84.1%, with a Delta T of 17.6°F; system capacity reading is blank.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge service visit
- HVAC
Built from Housecall Pro data
- HVACHVAC service call at 1980 Centurion Drive with no service lines listed and no charge.
- HVACPhotograph shows a Fluke 323 True RMS Clamp Meter displaying 0.9 A (AC) while clamped around wiring inside an HVAC air handler cabinet, with visible wiring harnesses and a control board in the background.
- HVACPhotograph shows a White-Rodgers by Copeland thermostat mounted on a wall, displaying a room temperature of 69°F with a set point of 75°F and Heat On active; the thermostat casing shows visible dirt and dark soiling.
- HVACMaintenance request submitted for heater not heating
- HVAC70581018, 115V, 60 Hz, 2750 RPM, P/N 348572, Cust P/N J238-100, UL Class B) mounted inside what appears to be a furnace or air handler cabinet, with foil-insulated ductwork visible in the background
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.