Hi, I'm 21 Gravois Bluffs Plaza Drive. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
21 Gravois Bluffs Plaza Drive
Across 1 record on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- HVAC · Air conditioner inspected, coils cleaned, refrigerant charge checked · Jul 2026
- HVAC · Contactor, capacitor, and motor outputs checked on AC unit · Jul 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 21 Gravois Bluffs Plaza Drive, Fenton, MO 63026, dated in July 2026. The amount summary includes $280 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Inspection and Maintenance — A/C inspection, coil cleaning
- HVAC
Built from Housecall Pro data
- $280HVACAir conditioning inspection and cleaning performed: checked air conditioner operation, cleaned coils, and checked refrigerant charge, contactor, capacitor and motor outputs.
- HVACPhotograph shows two pleated air filters installed side by side in an air handler filter slot; filters appear relatively clean with a light gray color.
- HVACPhotograph shows two side-by-side HVAC air filters installed in a return air plenum, both heavily loaded with accumulated dust, hair, and debris, indicating the filters are significantly clogged and due for replacement.
- HVACPhotograph shows HVAC condenser coil fin array with significant organic debris (leaves and dirt) fouling the fins across multiple rows, particularly in the upper sections of both coil columns.
- HVACPhotograph shows the interior of an outdoor HVAC condenser unit with curved corrugated coil fins exhibiting visible dirt and debris accumulation, particularly on the left side of the coil; the fan shroud and base pan are also visible.
- HVACPhotograph shows an HVAC air grille or filter with louvers heavily loaded with thick brown fibrous debris accumulation, indicating significant clogging and restricted airflow.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an HVAC condenser unit, displaying R410A refrigerant readings: superheat (SH) 20.8°F, subcooling (SC) 10.3°F, low-side pressure 119.0 psi, and high-side pressure 362.4 psi.
- HVAC47,000 BTU/hr cooling capacity, SEER 14, 80% thermal efficiency natural gas heat, 208/230V 3-phase power supply, AHRI Certified
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.