HVAC Inspection and Maintenance — A/C inspection, coil cleaning

  • HVAC

On July 27, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 21 Gravois Bluffs Plaza Drive, Fenton, MO 63026.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$280

    Air conditioning inspection and cleaning performed: checked air conditioner operation, cleaned coils, and checked refrigerant charge, contactor, capacitor and motor outputs.

  • HVACWork status not resolved

    Photograph shows two pleated air filters installed side by side in an air handler filter slot; filters appear relatively clean with a light gray color.

  • HVACWork status not resolved

    Photograph shows two side-by-side HVAC air filters installed in a return air plenum, both heavily loaded with accumulated dust, hair, and debris, indicating the filters are significantly clogged and due for replacement.

  • HVACWork status not resolved

    Photograph shows HVAC condenser coil fin array with significant organic debris (leaves and dirt) fouling the fins across multiple rows, particularly in the upper sections of both coil columns.

  • HVACWork status not resolved

    Photograph shows the interior of an outdoor HVAC condenser unit with curved corrugated coil fins exhibiting visible dirt and debris accumulation, particularly on the left side of the coil; the fan shroud and base pan are also visible.

  • HVACWork status not resolved

    Photograph shows an HVAC air grille or filter with louvers heavily loaded with thick brown fibrous debris accumulation, indicating significant clogging and restricted airflow.

  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge connected to an HVAC condenser unit, displaying R410A refrigerant readings: superheat (SH) 20.8°F, subcooling (SC) 10.3°F, low-side pressure 119.0 psi, and high-side pressure 362.4 psi.

  • HVACWork status not resolved

    47,000 BTU/hr cooling capacity, SEER 14, 80% thermal efficiency natural gas heat, 208/230V 3-phase power supply, AHRI Certified