2122 East Drive
Across 5 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 5 documented records
Fresh House Property Summary
Highlights selected from 5 documented records for this property.
- HVAC · Air conditioner, furnace, and evaporator coil replaced with new thermostat · Oct 2026
- HVAC · New condenser pad, disconnect, and flue pipe installed with the system · Oct 2026
- HVAC · Furnace pressure switch replaced to restore proper airflow · Jan 2026
- HVAC · Air conditioner capacitor replaced after diagnostic service · Jun 2026
- HVAC · Overtime diagnostic service performed on the HVAC system · Sep 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 5 documented records for 2122 East Drive, St. Louis, MO 63131, dated in January 2026. The amount summary includes $14,383.10 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Pressure Switch Replacement — Furnace pressure switch replaced
- HVAC
Built from Housecall Pro data
- $448HVACReplaced stocked pressure switch on the furnace to ensure proper airflow and prevent system shutdowns.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Service — Residential HVAC diagnostic service
- HVAC
Built from Housecall Pro data
- $89HVACDiagnostic service performed on the furnace; the pressure switch replacement line was listed with zero quantity and no charge.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Service — Diagnostic service, over 10 Mfd capacitor
- HVAC
Built from Housecall Pro data
- $349HVACResidential diagnostic service performed and an over 10 Mfd capacitor supplied.
- HVACPhotograph shows the open electrical compartment of an outdoor HVAC condenser unit with a Titan Pro dual-run capacitor (45+5 MFD, 440/370V) and a contactor, connected by multiple colored wires; unit exterior appears weathered and dirty.
- HVACPhotograph shows an outdoor HVAC condenser unit with access panel open, exposing multiple wires connected to a contactor or capacitor
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Service — Residential overtime diagnostic and labor
- HVAC
Built from Housecall Pro data
- $290HVACResidential overtime diagnostic and residential labor (non-member) performed.
- Unclassifiedprivate note indicates history should be reviewed for possible warranty and a new system estimate should be prepared
- HVACPhotograph shows a digital thermometer reading approximately 28°F being held against a galvanized metal HVAC duct, with silver foil tape visible at the duct seam and a wood structural member below.
- UnclassifiedPhotograph shows a screenshot of an iPhone Calculator app displaying the calculation 82-65 with a result of 17; no property-related content is present.
HVAC

Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Installation — 3-ton A/C + 80,000 BTU gas furnace
- HVAC
Built from Housecall Pro data
- $13,208HVACSupplied and installed a 3-ton American Standard 17 SEER2 air conditioner, 80,000 BTU gas furnace, evaporator coil, Sensi Wi-Fi thermostat, flue pipe, condenser pad and 30-amp disconnect, with journeyman and apprentice labor.
- HVACPhotograph shows a residential outdoor air conditioning condenser unit mounted on a concrete pad adjacent to the home's foundation wall, with a disconnect box and conduit visible on the wall; surrounding area has fallen leaves and bare soil.
- HVACPhotograph shows a gas furnace with sheet metal supply plenum and flue venting installed in a basement mechanical room; a condensate drain bucket is visible on the floor beneath the unit.
- HVACPhotograph shows an upflow gas furnace with an air handler/evaporator coil section above it, metal flue/exhaust vent pipes, copper refrigerant lines, a white condensate drain hose, a red-handled gas shutoff valve, and multiple service stickers affixed to the unit
- HVACPhotograph shows an outdoor air conditioning condenser unit positioned on bare ground against a concrete foundation wall, with a disconnect box mounted on the exterior wall above, refrigerant/electrical lines running into the structure, and a temporary canopy sheltering the unit during wet weather.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an HVAC condenser unit, displaying refrigerant R454B with superheat of 8.8°, subcooling of 12.1°, low-side pressure of 1337, and high-side pressure of 2640.
- HVACPhotograph shows a Testo 557 digital manifold gauge displaying R454B refrigerant readings: low-side 133.6 psig at 51.7°F and high-side 263.8 psig at 91.0°F, with the gauge positioned against HVAC equipment fins.
- HVAC11 oz. manufacture date shown on data plate is 8/2026
- HVACPhotograph shows a boxed furnace unit with model number S8V2B080M4PCBA and serial number 26334L4PHG, assembled in the USA, still in its original cardboard packaging.
- UnclassifiedHandwritten note on cardboard states device could not be programmed and was shipped unprogrammed
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.