Record 1Public property record

HVAC Pressure Switch Replacement — Furnace pressure switch replaced

  • HVAC

On January 30, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 2122 East Drive, St. Louis, MO 63131.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$448

    Replaced stocked pressure switch on the furnace to ensure proper airflow and prevent system shutdowns.

Record 2Public property record

HVAC Diagnostic Service — Residential HVAC diagnostic service

  • HVAC

On January 30, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 2122 East Drive, St. Louis, MO 63131.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$89

    Diagnostic service performed on the furnace; the pressure switch replacement line was listed with zero quantity and no charge.

Record 3Public property record

HVAC Diagnostic Service — Diagnostic service, over 10 Mfd capacitor

  • HVAC

On June 5, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 2122 East Drive, St. Louis, MO 63131.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$349

    Residential diagnostic service performed and an over 10 Mfd capacitor supplied.

  • HVACWork status not resolved

    Photograph shows the open electrical compartment of an outdoor HVAC condenser unit with a Titan Pro dual-run capacitor (45+5 MFD, 440/370V) and a contactor, connected by multiple colored wires; unit exterior appears weathered and dirty.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit with access panel open, exposing multiple wires connected to a contactor or capacitor

  • HVACWork status not resolved
Record 4Public property record

HVAC Diagnostic Service — Residential overtime diagnostic and labor

  • HVAC

On September 9, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 2122 East Drive, St. Louis, MO 63131.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$290

    Residential overtime diagnostic and residential labor (non-member) performed.

  • HVACWork status not resolved

    Photograph shows a digital thermometer reading approximately 28°F being held against a galvanized metal HVAC duct, with silver foil tape visible at the duct seam and a wood structural member below.

  • UnclassifiedWork status not resolved

    private note indicates history should be reviewed for possible warranty and a new system estimate should be prepared

  • UnclassifiedWork status not resolved

    Photograph shows a screenshot of an iPhone Calculator app displaying the calculation 82-65 with a result of 17; no property-related content is present.

Record 5Public property record

HVAC Installation — 3-ton A/C + 80,000 BTU gas furnace

  • HVAC

On October 15, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 2122 East Drive, St. Louis, MO 63131.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$13,208

    Supplied and installed a 3-ton American Standard 17 SEER2 air conditioner, 80,000 BTU gas furnace, evaporator coil, Sensi Wi-Fi thermostat, flue pipe, condenser pad and 30-amp disconnect, with journeyman and apprentice labor.

  • HVACWork status not resolved

    Photograph shows a residential outdoor air conditioning condenser unit mounted on a concrete pad adjacent to the home's foundation wall, with a disconnect box and conduit visible on the wall; surrounding area has fallen leaves and bare soil.

  • HVACWork status not resolved

    Photograph shows a gas furnace with sheet metal supply plenum and flue venting installed in a basement mechanical room; a condensate drain bucket is visible on the floor beneath the unit.

  • HVACWork status not resolved

    Photograph shows an upflow gas furnace with an air handler/evaporator coil section above it, metal flue/exhaust vent pipes, copper refrigerant lines, a white condensate drain hose, a red-handled gas shutoff valve, and multiple service stickers affixed to the unit

  • HVACWork status not resolved

    Photograph shows an outdoor air conditioning condenser unit positioned on bare ground against a concrete foundation wall, with a disconnect box mounted on the exterior wall above, refrigerant/electrical lines running into the structure, and a temporary canopy sheltering the unit during wet weather.

  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge connected to an HVAC condenser unit, displaying refrigerant R454B with superheat of 8.8°, subcooling of 12.1°, low-side pressure of 1337, and high-side pressure of 2640.

  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge displaying R454B refrigerant readings: low-side 133.6 psig at 51.7°F and high-side 263.8 psig at 91.0°F, with the gauge positioned against HVAC equipment fins.

  • HVACWork status not resolved

    11 oz. manufacture date shown on data plate is 8/2026

  • HVACWork status not resolved

    Photograph shows a boxed furnace unit with model number S8V2B080M4PCBA and serial number 26334L4PHG, assembled in the USA, still in its original cardboard packaging.

  • UnclassifiedWork status not resolved

    Handwritten note on cardboard states device could not be programmed and was shipped unprogrammed

  • HVACWork status not resolved