← MAP

214 Sugar Lake Drive

St. Peters, MO 6337638.7554°N, 90.5767°W
1Event
Contributed by:1 contributor
SOURCE-BACKED RECORDS
Exterior of 214 Sugar Lake Drive

Property History Report

Negotiate this home like you've seen its receipts. You have.

Free right now · built from this home's 1 documented records

Fresh House Property Summary

Highlights selected from 1 documented record for this property.

  • Electrical
    Electrical · Challenger panel has critical safety flaws, replacement recommended · 2026
  • Electrical
    Electrical · Open breaker slot and deck outlet need safety fixes · 2026
  • HVAC
    HVAC · Central cooling system working but needs annual professional servicing · 2026
  • Foundation
    Foundation · Concrete foundation and wall structure in satisfactory condition · 2026
  • Plumbing
    Plumbing · Water heater and copper pipes appear functional and in good shape · 2026
Ask this homePowered by Fresh House property intelligence®
Reading property memory…

RECORD SUMMARY

1 documented event
Contributed by: 1 contributor
First documented event: Aug 2026
Latest documented event: Aug 2026
First added to Fresh House: Aug 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 1 documented record for 214 Sugar Lake Drive, St. Peters, MO 63376, dated in August 2026.

Home Inspection

Home Inspection Document

Inspected Aug 14, 2026Uploaded Aug 14, 2026
Documented from uploaded report
Property Professional Uploaded

On August 14, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 2 other topics at 214 Sugar Lake Drive, St. Peters, MO 63376.

Scope
  • Electrical,
  • Foundation,
  • HVAC,
  • Home Inspection,
  • Plumbing
Contributor
worked on or inspected it
  • Home InspectionWhole-home inspection of condo at 214 Sugar Lake Dr found the property in great condition with no structural issues; deficiencies noted in electrical (Challenger panel, open breaker slot, deck GFCI outlet) and HVAC (annual service needed).
  • ElectricalChallenger electric panel (125-amp service) has critical safety flaws — breakers frequently fail to trip during overloads or short circuits — replacement recommended; open breaker slot needs a blank cover installed; rear deck outlet requires replacement with a GFCI-protected outlet.
  • FoundationSlab-on-grade poured concrete foundation and wood-frame wall structure both observed in satisfactory condition with no deficiencies noted.

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

Home Inspection
✓ documented
Plumbing
✓ documented
Foundation
✓ documented
Electrical
✓ documented
HVAC
✓ documented
Roof
undocumented
Sewer
undocumented
Mold
undocumented
Pest
undocumented
Radon
undocumented
Appraisals
undocumented
Windows
undocumented