Complete public upload archive

Property records for 2243 Bolton Street, St. Charles, MO 63301

All 1 public upload record returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 1.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

Document (07/21/2026)

  • Electrical
  • Foundation
  • HVAC
  • Home Inspection
  • Pest
  • Plumbing
  • Roof
  • Windows

On July 21, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 2243 Bolton Street, St. Charles, MO 63301.

Record date

Available findings

  • PestWork status not resolved

    Wood destroying insect inspection found visible termite damage on wood trim around the garage door; borate-based spray treatment recommended.

  • ElectricalWork status not resolved

    Newer Siemens 200-amp panel door blocked by plumbing line obstruction; one front bedroom outlet inoperable, one basement outlet has hot and neutral wires reversed; GFCI outlet missing at laundry washing machine circuit.

  • FoundationWork status not resolved

    Poured concrete basement foundation is in satisfactory condition; common cracks in corners noted and sealing with heavy-duty epoxy paste is recommended.

  • Home InspectionWork status not resolved

    Whole-home inspection of single-family property identified multiple deficiencies across site, exterior, electrical, HVAC, plumbing, and interior systems; no structural issues observed.

  • HVACWork status not resolved

    Goodman gas furnace manufactured 2017 is functional; 2-ton Carrier AC condenser manufactured 1998 has hit the end of its expected life and replacement is indicated.

  • PestWork status not resolved

    Older termite damage observed on overhead garage door trim; treatment with borate-based solution (Bora-Care) recommended unless seller proves prior treatment.

  • PlumbingWork status not resolved

    PVC cap on main sewer stack has stripped threads and needs replacement; toilet likely has a leaky flange with water dropping to basement floor when flushed; exterior faucet is loose; AO Smith 40-gal natural gas water heater manufactured 2022 is functional.

  • RoofWork status not resolved

    Architectural shingle roof estimated 3-5 years old is installed correctly and in satisfactory condition; one damaged wood fascia board on rear corner needs replacement.

  • WindowsWork status not resolved

    Bathroom window will not lock; the older locking mechanism needs to be replaced.