Hi, I'm 2243 Bolton Street. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
← MAPSOURCE-BACKED RECORDS
2243 Bolton Street
St. Charles, MO 6330138.7941°N, 90.5416°W
1Event
Contributed by:1 contributor

Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- HVAC · AC condenser from 1998 is past its expected life and needs replacement · 2026
- Electrical · Panel blocked, one outlet dead, one outlet wired backwards, GFCI missing · 2026
- Foundation · Basement foundation has corner cracks that should be sealed · 2026
- Plumbing · Sewer cap has stripped threads and toilet may be leaking to basement floor · 2026
- Pest · Visible termite damage found on garage door wood trim · 2026
Ask this homePowered by Fresh House property intelligence®
ASK ME ABOUT
RECORD SUMMARY
1 documented event
Contributed by: 1 contributor
First documented event: Jul 2026
Latest documented event: Jul 2026
First added to Fresh House: Jul 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
This page contains 1 documented record for 2243 Bolton Street, St. Charles, MO 63301, dated in July 2026.
Home Inspection
Home Inspection Document
Inspected Jul 21, 2026Uploaded Jul 24, 20262 files
Documented from uploaded report
Property Professional Uploaded
By
Greensmith Home Inspection llcdocumented Electrical, Foundation, HVAC, and 5 other topics at 2243 Bolton Street, St. Charles, MO 63301.
Scope
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Windows
Contributor
worked on or inspected it- Home InspectionWhole-home inspection of single-family property identified multiple deficiencies across site, exterior, electrical, HVAC, plumbing, and interior systems; no structural issues observed.
- PestWood destroying insect inspection found visible termite damage on wood trim around the garage door; borate-based spray treatment recommended.
- ElectricalNewer Siemens 200-amp panel door blocked by plumbing line obstruction; one front bedroom outlet inoperable, one basement outlet has hot and neutral wires reversed; GFCI outlet missing at laundry washing machine circuit.
- FoundationPoured concrete basement foundation is in satisfactory condition; common cracks in corners noted and sealing with heavy-duty epoxy paste is recommended.
- HVACGoodman gas furnace manufactured 2017 is functional; 2-ton Carrier AC condenser manufactured 1998 has hit the end of its expected life and replacement is indicated.
- PestOlder termite damage observed on overhead garage door trim; treatment with borate-based solution (Bora-Care) recommended unless seller proves prior treatment.
- PlumbingPVC cap on main sewer stack has stripped threads and needs replacement; toilet likely has a leaky flange with water dropping to basement floor when flushed; exterior faucet is loose; AO Smith 40-gal natural gas water heater manufactured 2022 is functional.
- RoofArchitectural shingle roof estimated 3-5 years old is installed correctly and in satisfactory condition; one damaged wood fascia board on rear corner needs replacement.
- WindowsBathroom window will not lock; the older locking mechanism needs to be replaced.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedFoundation
✓ documentedElectrical
✓ documentedHVAC
✓ documentedPest
✓ documentedWindows
✓ documentedSewer
undocumentedMold
undocumentedRadon
undocumentedAppraisals
undocumented