← MAP

2248 Kerwin Drive

St. Louis, MO 6313638.7445°N, 90.2472°W
1Event
Contributed by:1 contributor
SOURCE-BACKED RECORDS
Exterior of 2248 Kerwin Drive

Property History Report

Negotiate this home like you've seen its receipts. You have.

Free right now · built from this home's 1 documented records

Fresh House Property Summary

Highlights selected from 1 documented record for this property.

  • Electrical
    Electrical · Tree limbs on power lines and missing smoke detectors noted · 2026
  • HVAC
    HVAC · Attic fan too slow and likely needs replacement · 2026
  • Foundation
    Foundation · Basement foundation is solid with no moisture or structural issues · 2026
  • Plumbing
    Plumbing · Sewer line has sludge buildup and tree root intrusion · 2026
  • Roof
    Roof · Roof may have loose soffit on rear corner · 2026
Ask this homePowered by Fresh House property intelligence®
Reading property memory…

RECORD SUMMARY

1 documented event
Contributed by: 1 contributor
First added to Fresh House: Aug 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 1 documented record for 2248 Kerwin Drive, St. Louis, MO 63136.

DOCUMENTED

Home Inspection

Uploaded Aug 18, 2026
Documented from uploaded report
Property Professional Uploaded

Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 2248 Kerwin Drive, St. Louis, MO 63136.

Scope
  • Electrical,
  • Foundation,
  • HVAC,
  • Home Inspection,
  • Pest,
  • Plumbing,
  • Roof,
  • Windows
  • Home InspectionWhole-home inspection of single-family property found home in generally good condition with no structural issues; deficiencies noted include aged HVAC (2000/2002), sewer lateral sludge and root intrusion, loose soffit, tree limbs on power lines, missing smoke detectors, attic fan needing replacement, minor ceiling damage in rear bedroom, and one inoperable hallway outlet.
  • Electricaldeficiencies include tree limbs pushing on overhead power lines (power company contact recommended), missing smoke detectors throughout home, and one inoperable hallway outlet
  • FoundationPoured concrete basement foundation is satisfactory with no structural issues, no moisture detected, and previous basement wall repairs appeared effective.

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

Home Inspection
✓ documented
Roof
✓ documented
Plumbing
✓ documented
Foundation
✓ documented
Electrical
✓ documented
HVAC
✓ documented
Pest
✓ documented
Windows
✓ documented
Sewer
undocumented
Mold
undocumented
Radon
undocumented
Appraisals
undocumented

Nearby homes with documented history