Property records for 2725 Solway Avenue, Jennings, MO 63136

All 1 public upload record returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 1.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Estimate — a new 2.5 ton 13.4 SEER2 condenser

  • HVAC

On July 28, 2026, ASSURED HEATING AND COOLING documented HVAC at 2725 Solway Avenue, Jennings, MO 63136.

Record date

Available findings

  • HVACEstimate or proposed work$11,212

    Estimate for a new 2.5 ton 13.4 SEER2 condenser, TXV cased coil and 80% gas furnace, with a flue liner, new line set and theft deterrent cage, since the outdoor unit was stolen and the indoor unit has extreme wear; option marked declined.

  • HVACWork status not resolved

    Photograph shows a galvanized metal duct or flue pipe and partial HVAC equipment visible in the background of the same attic/utility space.

  • HVACWork status not resolved

    Photograph shows a basement mechanical area with a sheet-metal air handler/furnace unit, horizontal duct trunk with filter access panel, flexible metal duct elbow, and an insulated round flue pipe rising through the floor above.

  • HVACWork status not resolved

    Photograph shows a gray metal electrical junction/disconnect box mounted on the exterior wall at the siding-to-foundation transition, with a conduit exiting the bottom of the box terminating in an open, unsealed end with no protective bushing or fitting visible.

  • HVACWork status not resolved

    Photograph shows an open, unprotected crawl space or basement access opening cut into the concrete/stucco foundation wall, with exposed wood framing visible inside and no cover or door in place.

  • HVACWork status not resolved

    Photograph shows a damaged/bent gray metallic conduit protruding from exterior vinyl siding with an open, deteriorated wall penetration around it, a black electrical cable running unsecured across the siding face, and a gray meter base or disconnect enclosure mounted below.

  • HVACWork status not resolved

    Photograph shows white PVC drain/waste pipes with elbow fittings and a cleanout cap running along a painted concrete block basement wall, with blue PEX supply lines visible overhead at the floor joists.

  • HVACWork status not resolved

    Photograph shows an open residential electrical panel with two columns of circuit breakers, a main breaker at top bearing a yellow star sticker, a handwritten circuit directory on the door interior listing circuits including hot water, stove, and dryer, and visible rust/corrosion staining along the bottom of the breaker compartment.

  • HVACWork status not resolved

    Photograph shows a dusty furnace manufacturer data plate listing gas supply line pressure (max/min 3.5/3.2 in. W.C.), manifold pressure, temperature rise (30–60°F), max static pressure (0.0625 in. W.C.), and altitude range (0–4500 ft), with notes on LP/propane conversion kit requirements.

  • HVACWork status not resolved

    Photograph shows a large sheet metal HVAC duct or plenum with two visible holes or penetrations in its face, surrounded by deteriorated dark material consistent with degraded insulation or sealant, with multiple pipes running alongside.

  • HVACWork status not resolved

    Photograph shows a galvanized metal flue pipe elbow connecting into a large white tank or vessel, with the elbow joint insulation visibly cracked, crumbling, and deteriorated, and rust/corrosion present at the pipe-to-tank connection point.

  • HVACWork status not resolved

    Photograph shows a circular pipe opening set in a stone masonry cavity with heavily deteriorated interior lining — visible cracking, flaking, and corrosion on the pipe rim — along with accumulated debris and cobwebs at the pipe base.

  • HVACWork status not resolved

    Photograph shows a circular pipe penetration through a white-painted brick wall, with a dark pipe stub or cap visible inside the opening and no visible sealant or escutcheon plate around the penetration.

  • HVACWork status not resolved

    Photograph shows a white-painted brick column/pier in what appears to be a basement, with visible mortar joint deterioration and spalling on the column face; the adjacent masonry wall displays dark staining beneath the white paint coating.

  • HVACWork status not resolved

    Photograph shows a small bathroom with a white toilet and white vanity/cabinet unit in place; the back wall is unfinished, exposing bare plywood or OSB substrate with no finish wall covering applied.

  • HVACWork status not resolved

    Photograph shows extensive dark mold-like growth and discoloration covering a large area of the subfloor decking underside, visible from below in what appears to be a basement or crawlspace.

  • HVACWork status not resolved