HVAC Diagnostic and Refrigerant Service — Diagnostic and refrigerant
- HVAC
On June 12, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 2805 Parc Cheri Court, St. Louis, MO 63129.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$364
Performed a residential diagnostic service and added a refrigerant charge (410, 3 lbs max).
- HVACWork status not resolved
Fieldpiece app refrigerant side measurements show R-410A system with suction pressure 99.1 psig, liquid pressure 231.5 psig, actual superheat 31.9°F (elevated), and actual subcooling 0.3°F (very low), suggesting a possible refrigerant charge concern.
- HVACWork status not resolved
Photograph shows an outdoor HVAC condenser unit with coil fins visibly packed with heavy accumulation of dirt and debris, significantly restricting airflow through the louvered panel.
- HVACWork status not resolved
Photograph shows the exterior condenser coil fins of an outdoor HVAC unit with visible dirt, dust, and debris accumulation across the fin surface, most heavily concentrated in the upper section.
- HVACWork status not resolved
Photograph shows the exterior louvered panel of an outdoor HVAC condenser unit with fins visibly packed with heavy accumulations of dirt and debris, significantly restricting airflow through the coil.
- HVACWork status not resolved
Maintenance request logged for no air conditioning with indoor temperatures reported over 85 degrees.