- HVAC · AC diagnostic performed and refrigerant charge added · Jun 2026
- HVAC · AC was not cooling; indoor temps reported above 85°F · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 2805 Parc Cheri Court, St. Louis, MO 63129, dated in June 2026. The amount summary includes $364 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Diagnostic and Refrigerant Service — Diagnostic and refrigerant
- HVAC
Built from Housecall Pro data
- $364HVACPerformed a residential diagnostic service and added a refrigerant charge (410, 3 lbs max).
- HVACFieldpiece app refrigerant side measurements show R-410A system with suction pressure 99.1 psig, liquid pressure 231.5 psig, actual superheat 31.9°F (elevated), and actual subcooling 0.3°F (very low), suggesting a possible refrigerant charge concern.
- HVACPhotograph shows an outdoor HVAC condenser unit with coil fins visibly packed with heavy accumulation of dirt and debris, significantly restricting airflow through the louvered panel.
- HVACPhotograph shows the exterior condenser coil fins of an outdoor HVAC unit with visible dirt, dust, and debris accumulation across the fin surface, most heavily concentrated in the upper section.
- HVACPhotograph shows the exterior louvered panel of an outdoor HVAC condenser unit with fins visibly packed with heavy accumulations of dirt and debris, significantly restricting airflow through the coil.
- HVACMaintenance request logged for no air conditioning with indoor temperatures reported over 85 degrees.