- HVAC · AC condenser coil washed and refrigerant charge adjusted · Jul 2026
- HVAC · Resident reported water pooling in the AC system; probable clogged drain line · 2026
- HVAC · HVAC duct interiors show accumulated debris and discolored surfaces · 2026
- HVAC · Condenser coil fins heavily loaded with debris before July 2026 service · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 3 documented records for 2937 Sean Parkway, St. Louis, MO 63129, dated from July 2026 through August 2026. The amount summary includes $698 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Diagnostic and Service — Condenser coil washed, charge adjusted
- HVAC
Built from Housecall Pro data
- $290HVACPerformed a residential overtime diagnostic, washed the condenser coil and adjusted the charge.
- HVACPhotograph shows the exterior louvered grille and condenser coil fins of an outdoor air conditioning unit; the fins appear visibly dirty and coated with dust and debris accumulation.
- HVACPhotograph shows an outdoor HVAC condenser unit with heavily clogged louvered grille and coil fins packed with accumulated dust, lint, hair, and fibrous debris, significantly restricting airflow.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an R-22 outdoor condenser unit, displaying low-side pressure of 72.8 psi (superheat 9.3°F) and high-side pressure of 204.6 psi (subcooling 22.3°F).
- HVACPhotograph shows the interior of an HVAC unit with heavy accumulation of dust and lint on coiled tubing, insulation batting, metal brackets, and surrounding mechanical components.
- HVACwiring and metal housing are visible
- HVACPhotograph shows a metal vent grate with severely deteriorated, crumbling, and cracked wood visible behind and around it, consistent with significant wood damage.
- HVACPhotograph shows a heavily soiled air filter installed in a furnace/air handler unit, with a new replacement filter box visible on the floor nearby; the EnergyGuide label on the unit reads 80.0 AFUE.
- HVACPhotograph shows a heavily dust-laden HVAC air filter behind a louvered return-air grille; the filter media is uniformly dark brown with dense accumulation of dust, lint, and debris across its entire visible surface, and the grille slats also show significant dust buildup.
- HVACPhotograph shows a pipe passing through or adjacent to severely deteriorated wood framing in what appears to be a crawl space or subfloor area; the wood exhibits a rough, pitted, fibrous texture consistent with wood damage or pest activity.
- HVACProperty management app meld (work order) for an air conditioner issue showing two tenant/owner contacts; no work details, cost, or status are visible.
- HVACPhotograph shows an underground utility box containing heavily corroded brass shutoff valves and fittings covered in mineral deposits, dirt, and debris, with a wrench visible alongside the valves.
- HVACPhotograph shows a Testo 557 digital manifold gauge set connected to an HVAC system outdoors, displaying low-side pressure of approximately 73.8 psi, high-side pressure of 220.5 psi, and a subcooling (SC) reading of 23.2°F.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Trip fee and residential labor
- HVAC
Built from Housecall Pro data
- $219HVACTrip fee and residential labor (non-member) were provided at the service address.
- HVACResident reported water pooling in the A/C system; probable diagnosis is a clogged AC drain line. Resident turned off air conditioner and granted permission to enter.
- HVACPhotograph shows an aged HVAC unit using Refrigerant 22 (R-22) with heavy corrosion on the casing, a deteriorated/cracked refrigerant line fitting secured by a hose clamp, and foil tape applied around the lower unit housing.
- HVACMaintenance request for water pooling issue
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Service — Residential OT diagnostic
- HVAC
Built from Housecall Pro data
- $189HVACPerformed a residential OT diagnostic.
- HVACPhotograph shows an HVAC component (likely an evaporator coil, heat exchanger section, or louvered register) with extensive corrosion, rust, mineral scale buildup, and heavy fouling across its entire surface.
- HVACPhotograph shows a rectangular HVAC duct vent opening without a grille cover, with heavy dark debris accumulation and deteriorated surrounding material visible around the perimeter of the opening; horizontal damper blades are visible inside the duct.
- HVACPhotograph shows the interior of a rectangular metal air duct with significant dust and debris accumulation on the duct floor and walls, visible rust/corrosion along the lower seam, and scattered white fibrous material (possibly insulation debris) on the duct floor.
- HVACPhotograph shows the interior of a rectangular sheet metal air duct with heavy rust and orange-brown corrosion on the duct floor, white mineral or dust deposits along the floor-wall seam, and scattered debris visible further down the duct length.
- HVACPhotograph shows the interior of a rectangular sheet-metal air duct with visible dust and debris accumulation on the floor and textured dusty coating on the walls and ceiling; a faint light source or opening is visible at the far end.
- HVACPhotograph shows the interior of a large HVAC duct or plenum with extensive rust and corrosion on the metal floor, accumulated debris and particulate buildup, white mineral/chalky deposits along seams and corners, and a dark fibrous liner coating on the walls; a circular branch takeoff or damper is visible further down the duct.
- HVACPhotograph shows the interior of a rectangular sheet metal air duct (branded 'Wheeling') with visible dust and debris accumulation on the duct floor; the duct extends into darkness with no visible obstructions or damage to the duct walls.
- HVACPhotograph shows a rectangular ceiling duct opening with no grille cover installed; the interior duct walls and perimeter of the opening are heavily coated with dark dust, debris, and grime buildup.
- HVACPhotograph shows the interior of a narrow sheet-metal duct or air chase, with walls heavily coated in dust and grime; the bottom opening contains a substantial accumulation of debris including broken wood fragments and dark granular material.
- HVACPhotograph shows a ceiling HVAC duct boot opening with the register grille absent; the duct interior and surrounding ceiling surface exhibit heavy dark debris accumulation and dark staining around the perimeter of the opening.
- HVACPhotograph shows a removed HVAC vent register with an extremely heavily soiled, blackened filter/interior surface covered in dense accumulated dust, debris, and dark particulate buildup throughout.
- HVACPhotograph shows the interior of a large rectangular HVAC duct or plenum with heavy rust and corrosion on the floor and lower walls, significant accumulation of dust, debris, and white chalky buildup along the base, and visibly deteriorated rusted damper collars or branch takeoffs on the duct ceiling further down the run.
- HVAC · document contextPhotograph shows a textured (popcorn) ceiling surface with a visible circular discoloration or stain pattern in the center, where the texture appears darkened and flattened compared to the surrounding raised texture.
- HVAC · document contextPhotograph shows a large diffuse discoloration (darker gray-brown patch) on a popcorn/acoustic textured ceiling near the wall-ceiling junction, with a smooth painted wall below and a partially visible recessed light fixture in the lower left corner.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.