HVAC Diagnostic and Service — Condenser coil washed, charge adjusted
- HVAC
On July 5, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 2937 Sean Parkway, St. Louis, MO 63129.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$290
Performed a residential overtime diagnostic, washed the condenser coil and adjusted the charge.
- HVACWork status not resolved
Photograph shows the exterior louvered grille and condenser coil fins of an outdoor air conditioning unit; the fins appear visibly dirty and coated with dust and debris accumulation.
- HVACWork status not resolved
Photograph shows an outdoor HVAC condenser unit with heavily clogged louvered grille and coil fins packed with accumulated dust, lint, hair, and fibrous debris, significantly restricting airflow.
- HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge connected to an R-22 outdoor condenser unit, displaying low-side pressure of 72.8 psi (superheat 9.3°F) and high-side pressure of 204.6 psi (subcooling 22.3°F).
- HVACWork status not resolved
Photograph shows the interior of an HVAC unit with heavy accumulation of dust and lint on coiled tubing, insulation batting, metal brackets, and surrounding mechanical components.
- HVACWork status not resolved
wiring and metal housing are visible
- HVACWork status not resolved
Photograph shows a metal vent grate with severely deteriorated, crumbling, and cracked wood visible behind and around it, consistent with significant wood damage.
- HVACWork status not resolved
Photograph shows a heavily soiled air filter installed in a furnace/air handler unit, with a new replacement filter box visible on the floor nearby; the EnergyGuide label on the unit reads 80.0 AFUE.
- HVACWork status not resolved
Photograph shows a heavily dust-laden HVAC air filter behind a louvered return-air grille; the filter media is uniformly dark brown with dense accumulation of dust, lint, and debris across its entire visible surface, and the grille slats also show significant dust buildup.
- HVACWork status not resolved
Photograph shows a pipe passing through or adjacent to severely deteriorated wood framing in what appears to be a crawl space or subfloor area; the wood exhibits a rough, pitted, fibrous texture consistent with wood damage or pest activity.
- HVACWork status not resolved
- HVACWork status not resolved
Property management app meld (work order) for an air conditioner issue showing two tenant/owner contacts; no work details, cost, or status are visible.
- HVACWork status not resolved
Photograph shows an underground utility box containing heavily corroded brass shutoff valves and fittings covered in mineral deposits, dirt, and debris, with a wrench visible alongside the valves.
- HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge set connected to an HVAC system outdoors, displaying low-side pressure of approximately 73.8 psi, high-side pressure of 220.5 psi, and a subcooling (SC) reading of 23.2°F.