← MAP

2937 Queen Bee Lane

St. Louis, MO 6312938.4330°N, 90.3244°W
4Events
Contributed by:1 contributor
$14kDocumented amounts
SOURCE-BACKED RECORDS

Across 4 records on this home

Completed work

Invoices and paid receipts

$14k

Estimated · not confirmed

Quotes, estimates, and other amounts not confirmed as performed

None documented yet

Property History Report

Negotiate this home like you've seen its receipts. You have.

Free right now · built from this home's 4 documented records

Fresh House Property Summary

Highlights selected from 4 documented records for this property.

  • HVAC
    HVAC · New HVAC Elite System and humidifier installed · Oct 2025$14k
  • HVAC
    HVAC · Return air covers supplied and added to the system · Nov 2025
  • HVAC
    HVAC · Air conditioner maintenance performed on new equipment · May 2026
Ask this homePowered by Fresh House property intelligence®
THE HOME

Hi, I'm 2937 Queen Bee Lane. I only speak from this property's source-backed records — 4 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.

ASK ME ABOUT

RECORD SUMMARY

4 documented events
Contributed by: 1 contributor
First documented event: Oct 2025
Latest documented event: Feb 2026
First added to Fresh House: Nov 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 4 documented records for 2937 Queen Bee Lane, St. Louis, MO 63129, dated from October 2025 through February 2026. The amount summary includes $13,971 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.

HVAC

HVAC System Installation — Elite System install with humidifier

Document dated Oct 2, 2025Uploaded Nov 8, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 2937 Queen Bee Lane, St. Louis, MO 63129.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $13,821
  • HVACInstalled an Elite System and a humidifier at the service address.
    $13,821

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Return Air Covers — Return air covers

Document dated Nov 9, 2025Uploaded Nov 8, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 2937 Queen Bee Lane, St. Louis, MO 63129.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $150
  • HVACReturn air covers were supplied.
    $150

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Service Invoice — No-charge service visit, no line items

Document dated Feb 2, 2026Uploaded Nov 8, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 2937 Queen Bee Lane, St. Louis, MO 63129.
Scope
  • HVAC
Contributor
worked on or inspected it

Built from Housecall Pro data

  • HVACInvoice for a service visit at the property with no service lines listed.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Maintenance Invoice — Air conditioner maintenance, new equipment

Document dated May 28, 2026Uploaded Nov 8, 20263 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 2937 Queen Bee Lane, St. Louis, MO 63129.
Scope
  • HVAC

Built from Housecall Pro data

  • HVACPerformed air conditioner maintenance on new equipment.
  • HVACPhotograph shows a Testo digital manifold gauge connected to an HVAC condenser unit displaying R-454B refrigerant readings: low-side pressure 102.0 psi, high-side pressure 247.9 psi, evaporator temperature 37.5°F, condensing temperature 86.8°F, T2 probe 74.0°F, and subcooling 12.8°F.
  • HVACPhotograph shows a ThermoPro digital thermometer reading 59°F being held in a mechanical space with visible HVAC equipment (furnace/air handler) and sheet metal ductwork in the background.
Attached photo 1HVAC
Attached photo 2HVAC

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

HVAC
✓ documented
Home Inspection
undocumented
Roof
undocumented
Plumbing
undocumented
Sewer
undocumented
Foundation
undocumented
Mold
undocumented
Electrical
undocumented
Pest
undocumented
Radon
undocumented
Appraisals
undocumented
Windows
undocumented