Record 1Public property record

HVAC System Installation — Elite System install with humidifier

  • HVAC

On October 2, 2025, JLM HEATING AND AIR CONDITIONING documented HVAC at 2937 Queen Bee Lane, St. Louis, MO 63129.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$13,821

    Installed an Elite System and a humidifier at the service address.

Record 2Public property record

HVAC Return Air Covers — Return air covers

  • HVAC

On November 9, 2025, JLM HEATING AND AIR CONDITIONING documented HVAC at 2937 Queen Bee Lane, St. Louis, MO 63129.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$150

    Return air covers were supplied.

Record 3Public property record

HVAC Service Invoice — No-charge service visit, no line items

  • HVAC

On February 2, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 2937 Queen Bee Lane, St. Louis, MO 63129.

Record date

Available findings

  • HVACCompleted work

    Invoice for a service visit at the property with no service lines listed.

Record 4Public property record

HVAC Maintenance Invoice — Air conditioner maintenance, new equipment

  • HVAC

On May 28, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 2937 Queen Bee Lane, St. Louis, MO 63129.

Record date

Available findings

  • HVACCompleted work

    Performed air conditioner maintenance on new equipment.

  • HVACWork status not resolved

    Photograph shows a Testo digital manifold gauge connected to an HVAC condenser unit displaying R-454B refrigerant readings: low-side pressure 102.0 psi, high-side pressure 247.9 psi, evaporator temperature 37.5°F, condensing temperature 86.8°F, T2 probe 74.0°F, and subcooling 12.8°F.

  • HVACWork status not resolved

    Photograph shows a ThermoPro digital thermometer reading 59°F being held in a mechanical space with visible HVAC equipment (furnace/air handler) and sheet metal ductwork in the background.

View 2937 Queen Bee Lane, St. Louis, MO 63129 on Fresh House