On July 7, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 3 Revolutionary Way Court, O'Fallon, MO 63366.
- Record date
Available findings
- SewerWork status not resolved
No blockages or damages observed in sewer lines; a small indentation is present in the PVC roughly 10' in from the city main tap, with re-scoping recommended in two years to monitor for growth.
- Home InspectionWork status not resolved
Whole-home inspection of single-family property found no structural issues overall, but identified multiple deficiencies across roofing, foundation, electrical, pest, and other systems requiring attention.
- FoundationWork status not resolved
Multiple common cracks present in the basement foundation wall; three cracks are allowing moisture intrusion and need epoxy injections, with smaller cracks to be filled with urethane; sloped rear patio brickwork may be promoting moisture intrusion on the rear-facing basement wall.
- RoofWork status not resolved
Architectural shingle roof estimated 20-25 years old (possibly original) is performing but shows signs of age and hail damage; drone inspection conducted.
- ElectricalWork status not resolved
Three exterior GFCI outlets have no power (possibly downstream from a hidden GFCI); laundry room lacks GFCI-protected outlet; 200-amp Murray service panel in basement appears functional.
- HVACWork status not resolved
Carrier central split system (77,000 BTU furnace mfgd 2016, 3-ton condenser mfgd 2015) performs properly but requires annual cleaning and servicing; two bathroom exhaust fans vent into the attic and need extension to exterior.
- PlumbingWork status not resolved
General Electric 50-gallon natural gas water heater manufactured in 2007 is functioning properly; pool pump base has a crack and likely needs replacement as the casing is nearly impossible to repair.
- PestWork status not resolved
Older termite damage is present on a front yard tree stump; inspector recommends removing the stump or treating with a borate-based solution such as Bora-Care.
- PestWork status not resolved
WDI inspection of SFR/Attached Garage at 3 Revolutionary Way Court, O'Fallon, MO found older termite damage on a front yard tree stump; treatment recommended — spray the area with a borate-based solution.